Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add LATA graph refinement and failure-aware score to SCP (ablation) | split conformal prediction (LAC) · 9 medical tasks, alpha=0.10 | avg set size: 3.99 -> 3.07 | Improved |
| add LATA graph refinement (no ViLU) to SCP (ablation) | SCP (LAC) · alpha=0.10 | set size / CCV: Size 3.99 -> 3.14; CCV 9.96 -> 6.65 | Improved |
| add ViLU failure-aware score on top of LATA refinement (ablation) | LATA (no ViLU) · LAC alpha=0.10 | set size / CCV: Size 3.14 -> 3.07; CCV 6.65 -> 6.40 | Improved |
| add only the ViLU risk term u to SCP (ablation) | SCP (LAC) · alpha=0.10 | set size / CCV: Size 3.99 -> 3.95; CCV 9.96 -> 9.15 | Mixed |
| add only image-conditioned alpha term to SCP (ablation) | SCP (LAC) · alpha=0.10 | set size / CCV: Size 3.99 -> 3.60; CCV 9.96 -> 8.85 | Mixed |
| use LATA instead of SCA-T | transductive conformal · APS alpha=0.10 | set size / CCV / ACA: Size 3.35 -> 2.95; CCV 7.18 -> 6.32; ACA 55.2 -> 57.1 | Improved |
| turn on calibration-marginal prior (beta=0.2, LATA-LI) (ablation) | LATA-LF · APS alpha=0.10 | coverage / size: coverage 0.900 -> 0.910; size 2.95 -> 3.03 | Mixed |
| fit linear probe on calibration labels then SCP on same split (Adapt+SCP) | SCP · APS alpha=0.10 | coverage: 0.900 -> 0.858 | Hurt |
| use LATA instead of TransCLIP/TIM | transductive solvers · LAC alpha=0.10 | coverage: TransCLIP 0.726 vs LATA-LF 0.900 | Improved |
| increase window size W from 64 to 512 (ablation) | LATA · LAC alpha=0.10 | set size: ~3.12 -> ~3.06 | No clear effect |
| increase calibration shots K from 4 to 16 (ablation) | LATA · LAC alpha=0.10 | set size: 3.18 -> 3.08 | Improved |
| use LATA refinement instead of SCA-T/TIM for compute | transductive solvers · LAC alpha=0.10 | runtime (s): 1.04 -> 0.05 (vs SCA-T) | Improved |
Closest papers by meaning
- Conformal Prediction for Zero-Shot Models (CVPR 2025 · similarity 0.87)
- Scaling Full Conformal Image Classifiers (NeurIPS 2026 · similarity 0.87)
- How Do Medical MLLMs Fail? A Study on Visual Grounding in Medical Images (ICLR 2026 · similarity 0.86)
- An Empirical Study Into What Matters for Calibrating Vision-Language Models (ICML 2024 · similarity 0.85)
- Free on the Fly: Enhancing Flexibility in Test-Time Adaptation with Online EM (CVPR 2025 · similarity 0.85)
- Uncertainty Estimation for Pretrained Medical Image Registration Models via Transformation Equivariance (NeurIPS 2026 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.