AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

BiomedCCPL: Causal Conditional Prompt Learning for Biomedical Vision-Language Models

Xueliang Cui, Juncai Zhang, Jiacheng Hou, Dan Lu, Hao Zhang, Ruxin Wang

CVPR 2026 · Vision-language and multimodal › CLIP and zero-shot · approach: Prompt learning for CLIP

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add SCD to the CoOp baseline (ablation)CoOp baseline · Base-to-Novel, avg 11 datasetsNovel accuracy (%): 64.72 -> 75.69Improved
add VGAP to the CoOp baseline (ablation)CoOp baseline · Base-to-Novel, avg 11 datasetsNovel accuracy (%): 64.72 -> 73.26Improved
add SAR to the CoOp baseline (ablation)CoOp baseline · Base-to-Novel, avg 11 datasetsNovel accuracy (%): 64.72 -> 65.68Improved
add VGAP to SAR + SCD (ablation)BiomedCCPL · Few-shot, avg 11 datasets, 16-shotaccuracy (%): 71.13 -> 82.25Improved
add SCD to SAR + VGAP (ablation)BiomedCCPL · Few-shot, avg 11 datasets, 16-shotaccuracy (%): 79.80 -> 82.25Improved
add SAR to VGAP + SCD (ablation)BiomedCCPL · Few-shot, avg 11 datasets, 16-shotaccuracy (%): 77.48 -> 82.25Improved
add SCD to SAR + VGAP (ablation)BiomedCCPL · Base-to-Novel, avg 11 datasetsNovel accuracy (%): 73.87 -> 79.20Improved
add SAR to VGAP alone for few-shot (ablation)VGAP only · Few-shot, avg 11 datasets, 16-shotaccuracy (%): 79.95 -> 79.80No clear effect
add adaptive prototypes in VGAP (ablation)BiomedCCPL · Base-to-Novel, avg 11 datasetsHM (%): 76.91 -> 79.98Improved
add adaptive prototypes in VGAP (ablation)BiomedCCPL · Few-shot, avg 11 datasets, 16-shotaccuracy (%): 78.20 -> 82.25Improved
use BiomedCCPL instead of BiomedCoOp on novel classesBase-to-Novel · Base-to-Novel, avg 10 datasetsNovel accuracy (%): 70.46 -> 79.20Improved
use BiomedCCPL instead of MMA on harmonic meanBase-to-Novel · Base-to-Novel, avg 10 datasetsHM (%): 73.53 -> 79.98Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy