AI Paper Atlas

Research map / Image generation / Autoregressive and latent generation

Anatomica: Localized Control over Geometric and Topological Properties for Anatomical Diffusion Models

Karim Kadry, Abdalla Abdelwahed, Ajay Manicka, Naravich Chutisilp, Farhad R. Nezami, Elazer R. Edelman

CVPR 2026 · Image generation › Autoregressive and latent generation · approach: Equivariant diffusion for 3D molecules · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
guide unconditional diffusion with topological potentialsAnatomica-L · Atrial SeparationB0 precision (%): 7.81 -> 78.9Improved
guide unconditional diffusion with topological potentialsAnatomica-L · Calcium CountB0 precision (%): 0.00 -> 60.9Improved
guide unconditional diffusion with topological potentialsAnatomica-L · Vertebrae ConnectivityB1 precision (%): 8.59 -> 26.6Improved
guide unconditional diffusion with topological potentialsAnatomica-L · Vertebrae ConnectivityB2 precision (%): 12.5 -> 7.03Hurt
guide unconditional diffusion with topological potentialsAnatomica-L · Atrial Separation1-NNA: 0.578 -> 0.606Hurt
use inference-time geometric guidance instead of explicit conditioningAnatomica-L · Right VentricleMass error (x1e5): 154.5 -> 17.5Improved
use inference-time geometric guidance instead of implicit conditioningAnatomica-L · Mitral ValveFMD: 314.8 -> 88.8Improved
use guidance instead of implicit conditioningAnatomica-L · Aortic TrunkMass error (x1e5): 0.81 -> 2.38Hurt
use neural field decoder with L-parsing instead of convolutional decoder with V-parsing (ablation)Anatomica-L · Mitral ValveCentroid error (x1e4): 41.4 -> 11.4Improved
use neural field decoder with L-parsing instead of convolutional decoder with V-parsing (ablation)Anatomica-L · Right VentricleMass error (x1e5): 12.3 -> 17.5Hurt
reduce local L-parsing resolution from high to low (ablation)Anatomica-L · Right Ventriclerelative speed: 2.48 -> 10.40Improved
reduce local L-parsing resolution from high to low (ablation)Anatomica-L · Right VentricleFMD: 91.16 -> 105.57Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy