Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use S4 backbone instead of Net1D CNN in supervised training | supervised baseline · PTB-XL (all) | macro AUROC: 0.929 -> 0.941 | Improved |
| use ECG-CPC SSM foundation model instead of supervised S4 | finetuning · PTB-XL (all) | macro AUROC: 0.941 -> 0.949 | Improved |
| use ECG-CPC instead of supervised S4 | finetuning · EchoNext (Echo) | macro AUROC: 0.819 -> 0.831 | Improved |
| use ECG-FM instead of supervised S4 | finetuning · MIMIC (Age) | standardized MAE: 0.455 -> 0.412 | Improved |
| use ST-MEM foundation model instead of supervised S4 | finetuning · MIMIC (Age) | standardized MAE: 0.455 -> 0.504 | Hurt |
| pretrain HuBERT-ECG with masked language modeling at 9.1M samples instead of S4 from scratch | finetuning · MIMIC (Age) | standardized MAE: 0.455 -> 0.579 | Hurt |
| pretrain with ECG-JEPA instead of training S4 from scratch (label efficiency) | EchoNext scaling · EchoNext | label efficiency ratio: 0.11-0.42 | Improved |
| pretrain with ECG-CPC instead of S4 from scratch (label efficiency) | EchoNext scaling · EchoNext | label efficiency ratio: 0.21-0.40 | Improved |
| pretrain with ECGFounder instead of S4 from scratch (label efficiency) | EchoNext scaling · EchoNext | label efficiency ratio: 0.30-0.62 | Improved |
| add layer-dependent learning rates in finetuning (ablation) | finetuned FMs · PTB-XL, EchoNext, CPSC-Extra | performance | Improved |
| use 2.5-second crops with test-time averaging instead of full 10-second inputs (ablation) | finetuning · ECG benchmark | performance | Improved |
| use linear head instead of learnable query-attention head in frozen evaluation for ECG-CPC | ECG-CPC · ECG benchmark | ranking | Hurt |
Closest papers by meaning
- ECG-Reasoning-Benchmark: A Benchmark for Evaluating Clinical Reasoning Capabilities in ECG Interpretation (NeurIPS 2026 · similarity 0.89)
- From Token to Rhythm: A Multi-Scale Approach for ECG-Language Pretraining (ICML 2025 · similarity 0.89)
- GEM: Empowering MLLM for Grounded ECG Understanding with Time Series and Images (NeurIPS 2025 · similarity 0.88)
- Extending Pretrained 10-Second ECG Foundation Models to Longer Horizons (NeurIPS 2026 · similarity 0.88)
- ECG-R1: Protocol-Guided and Modality-Agnostic MLLM for Reliable ECG Interpretation (ICML 2026 · similarity 0.87)
- anyECG-chat: A Generalist ECG-MLLM for Flexible ECG Input and Multi-Task Understanding (AAAI 2026 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.