Introduces MedThinkVQA, an expert-annotated radiology benchmark of 8,067 multi-image Eurorad cases (6.62 images/case) with per-image findings, integrated summaries, and stepwise/beyond-accuracy evaluation, showing top VLMs reach only ~57% accuracy.
Problem
Medical VQA benchmarks mostly use single images and answer-only scoring, whereas real diagnosis requires grounding, aligning, and composing evidence across multiple images; existing benchmarks lack multi-image density and stepwise supervision.
Approach
A multi-image diagnostic benchmark built from expert-annotated Eurorad cases with a three-step think-with-images supervision (per-image findings, case-level integrated summary, differential-diagnosis reasoning), filtered against text-solvable shortcuts and option-length bias, plus step-level LLM-judge and human evaluation.
Key results
- Best test accuracy is Claude-4.6-Opus at 57.2%, followed by Gemini-3-Pro at 55.3% and GPT-5.2 (xhigh) at 54.9%; top open model Qwen3.5-397B-A17B reaches 52.2%.
- Adding expert integrated imaging summaries raises accuracy by +41.5 to +50.5 points across MedGemma-27B and GPT-5 family models, while self-generated hints/summaries consistently reduce accuracy.
- Over 70% of step errors are image-understanding errors (69.23% on critical error-bearing steps); human expert accuracy on a 96-case subset is 77.10%.
Surprising findings
- Self-generated image descriptions or summaries consistently hurt accuracy across all tested models, despite expert versions giving large gains.
- Extra reasoning tokens help only for models with reliable visual grounding; small Qwen3.5 and Qwen3-VL models show flat or unstable gains, and Qwen3.5-0.8B's reasoning can reiterate misreadings.
Limitations
- Single educational source (Eurorad) with possible distribution shift across hospitals and populations; English-only.
- Test set is 720 cases and LLM-judge components may be prompt-sensitive and carry judge bias; human study covers only 50 cases and 96 cases.
- Multiple-choice setting simplifies real diagnostic work; rare diseases and some specialties underrepresented.
Experimental setup
Datasets: Eurorad
Benchmarks: MedThinkVQA
Metrics: accuracy ROUGE-L RadCliQ-v1 step-level factual correctness error-type coverage rubric score MELD
Baselines: Claude-4.6-Opus Gemini-3-Pro GPT-5.2 GPT-5-mini GPT-5-nano Qwen3.5-397B-A17B Qwen3.5-27B Lingshu-32B InternVL3.5-38B MedGemma-27B
Builds on: Eurorad MedXpertQA chain-of-thought
Closest papers by meaning
- MedAtlas: Evaluating LLMs for Multi-Round, Multi-Task Medical Reasoning Across Diverse Imaging Modalities and Clinical Text (AAAI 2026 · similarity 0.91)
- Med-CMR: A Fine-Grained Benchmark Integrating Visual Evidence and Clinical Logic for Medical Complex Multimodal Reasoning (CVPR 2026 · similarity 0.91)
- OpenMedReason: Scientific Reasoning Supervision for Medical Vision–Language Models (NeurIPS 2026 · similarity 0.91)
- M3CoTBench: Benchmark Chain-of-Thought of MLLMs in Medical Image Understanding (ICLR 2026 · similarity 0.90)
- Visual and Domain Knowledge for Professional-level Graph-of-Thought Medical Reasoning (ICML 2025 · similarity 0.89)
- CARE: Towards Clinical Accountability in Multi-Modal Medical Reasoning with an Evidence-Grounded Agentic Framework (ICLR 2026 · similarity 0.89)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.