atlas

Research map / Image generation / Image restoration

High-Resolution Image Harmonization with Adaptive-Interval Color Transformation

NeurIPS 2024 · Image generation › Image restoration · approach: Image harmonization and color transformation · 3 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes AICT, a lightweight transformer-based method that predicts position-dependent 3D LUTs at low resolution and uses adaptive sampling intervals plus a global weight module for pixel-wise color transformation in high-resolution image harmonization.

Problem

High-resolution image harmonization methods rely on global color adjustments or upsampled parameter maps, which ignore local variations and cause inharmonious results at full resolution.

Approach

Predict pixel-wise color transformations as position-dependent 3D LUTs from low-resolution inputs, cascade two such LUTs so the first redistributes color values to adaptively set sampling intervals for the second, and add a global image-level weight learning module to model overall brightness/color shifts from background.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use AICT instead of PCT-NetiHarmony4 · iHarmony4 full-resolution, AllfMSE: 238.27 -> 228.43Helped
use AICT instead of PCT-NetiHarmony4 · iHarmony4 full-resolution, AllSSIM: 0.9911 -> 0.9910No clear effect
use AICT instead of PCT-NetiHarmony4 · iHarmony4 256 × 256, AllfMSE: 216.25 -> 204.67Helped
use AICT instead of CDTNet-256HAdobe5k · HAdobe5k 1024 × 1024fMSE: 152.13 -> 156.81Hurt
remove adaptive interval learning (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 239.34Hurt
use 2 LUTs for adaptive interval learning (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 241.79Hurt
use 3 LUTs for adaptive interval learning (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 231.91Hurt
use multiple LUTs for color transformation (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 456.98; 228.43 -> 487.60Hurt
use global RGB-to-RGB transformations instead of pixel-wise transformations (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 357.61Hurt
remove global consistent weight learning module (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 247.48Hurt
predict spatially varying weight parameters (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 230.24Hurt
set number of knots K to 6 (ablation)AICT · iHarmony4 full-resolution, AllfMSE: 228.43 -> 241.67Hurt

Surprising findings

Limitations

Experimental setup

Datasets: iHarmony4 ccHarmony HAdobe5k real composite dataset (Cong et al. / CDTNet)

Benchmarks: iHarmony4 full-resolution iHarmony4 256x256 HAdobe5k 1024/2048 resolution HAdobe5k over4K/over5K ccHarmony 256x256 real composite dataset

Metrics: fMSE MSE PSNR SSIM FLOPs memory inference time user study score

Baselines: AdaInt SepLUT Harmonizer DCCF PCT-Net CDTNet S2CRNet iS2AM GiftNet

Builds on: AdaInt SepLUT PCT-Net DoveNet

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy