atlas

Research map / Label-efficient and robust learning / Test-time adaptation

Dual-frame Fluid Motion Estimation with Test-time Optimization and Zero-divergence Loss

NeurIPS 2024 · Label-efficient and robust learning › Test-time adaptation · approach: Extrapolation and single-sample adaptation · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes a fully self-supervised dual-frame 3D fluid motion estimator with a splat-based zero-divergence loss and a test-time residual optimization module (DVE), matching or beating supervised methods with 1% of training samples and no labels.

Problem

Dual-frame 3D particle tracking velocimetry (PTV) fluid motion estimation relies on large fully labeled datasets, which are costly to collect, and supervised models generalize poorly across domains.

Approach

Train a graph-based optimal-transport flow estimator purely self-supervised using reconstruction, smoothness, and a zero-divergence loss computed by splatting unstructured particle flows onto a uniform grid; then refine the flow on each test input via a test-time residual optimization (DVE) using only the reconstruction loss.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use the proposed method instead of GotFlow3DFluidFlow3D motion estimation · Forced MHD TurbulenceEPE: 0.00596 -> 0.0037Helped
use the proposed method instead of GotFlow3DFluidFlow3D motion estimation · Forced Isotropic TurbulenceEPE: 0.01153 -> 0.0117Hurt
use the proposed method instead of GotFlow3DFluidFlow3D motion estimation · Turbulent Channel FlowEPE: 0.00241 -> 0.0019Helped
train the proposed method with 1% rather than all training dataOurs on FluidFlow3D · FluidFlow3D test dataEPE: 0.00460 -> 0.00850Hurt
use Ours+Fm initialization instead of Fm-track aloneFm-track on AVIC · AVIC C2NMNDS: 0.283 -> 0.246Helped
use Ours+Fm initialization instead of Fm-track aloneFm-track on AVIC · AVIC E2Ntracked matches: 8097 -> 8097No clear effect
use Ours+Fm initialization instead of Fm-track aloneFm-track on AVIC · AVIC C2Etracked matches: 8040 -> 8048Helped

Surprising findings

Limitations

Experimental setup

Datasets: FluidFlow3D DeformationFlow AVIC

Benchmarks: FluidFlow3D DeformationFlow AVIC

Metrics: EPE NEPE Acc Strict Acc Relax Outliers Matches Tracking ratio neighbor distance score

Baselines: FlowNet3D FLOT PointPWC-Net PV-RAFT GotFlow3D

Builds on: GotFlow3D FLOT Chamfer distance EdgeConv

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy