Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| replace Fixed U-Net with SSHN hypernetwork | U-Net · CAMUS test | Dice (%): 83.5 -> 86.2 | Improved |
| replace Fixed U-Net with SSHN hypernetwork | U-Net · OASIS test | Dice (%): 89.1 -> 90.7 | Improved |
| replace Fixed U-Net with SSHN hypernetwork | U-Net · PanDental test | Dice (%): 88.9 -> 89.9 | Improved |
| replace Fixed U-Net with SSHN hypernetwork | U-Net · WBC test | Dice (%): 90.9 -> 92.7 | Improved |
| use stochastic rescaling factor during training of a plain U-Net instead of fixed | U-Net · OASIS test | Dice (%): 89.1 -> 84.8 | Hurt |
| add FiLM conditioning on stochastically sampled rescaling factor instead of fixed | U-Net · OASIS test | Dice (%): 89.1 -> 87.2 | Hurt |
| stochastic rescaling vs fixed on CAMUS | U-Net · CAMUS test | Dice (%): 83.5 -> 83.3 | No clear effect |
| widen the training prior of phi from r=0 (constant 0.5) to wider uniform range (ablation) | SSHN · OASIS test, evaluated at phi=0.5 | Dice | Improved |
| train SSHN with r = 0 (constant phi = 0.5) (ablation) | SSHN · OASIS test, phi=0.5 | Dice | Hurt |
| widen prior to U(0.4, 0.6) beyond narrow ranges (ablation) | SSHN · OASIS test | Dice | No clear effect |
| reduce rescaling factor from 0.5 to 0.4 | SSHN · OASIS and PanDental | inference FLOPs: over 50% reduction | Improved |
| reduce rescaling factor from 0.5 to 0.3 | SSHN · OASIS and PanDental | inference FLOPs: 70% reduction | Improved |
Closest papers by meaning
- EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks (ICML 2019 · similarity 0.86)
- Streaming Convolutional Neural Networks for End-to-End Learning With Multi-Megapixel Images (TPAMI 2020 · similarity 0.86)
- Scaling Recurrent Models via Orthogonal Approximations in Tensor Trains (ICCV 2019 · similarity 0.86)
- LVM-Med: Learning Large-Scale Self-Supervised Vision Models for Medical Imaging via Second-order Graph Matching (NeurIPS 2023 · similarity 0.86)
- LoMix: Learnable Weighted Multi-Scale Logits Mixing for Medical Image Segmentation (NeurIPS 2025 · similarity 0.84)
- The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical Images (ICLR 2024 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.