Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · IDT, 15 dB input SNRSNR (dB): 40.54 -> 40.57No clear effect
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · Sparse-view CT, 90 viewsSNR (dB): 34.61 -> 34.40Hurt
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · MRI Set1, 10% samplingSNR (dB): 24.10 -> 24.08No clear effect
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · IDT, 20 dB input SNRGPU test time: 6.362s -> 2.051sImproved
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · Sparse-view CT, 180 viewsGPU test time: 5.466s -> 3.113sImproved
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · MRI, 320×320 image, 96 coilsGPU test time: 4.577s -> 3.005sImproved
Use stochastic minibatches of measurements in the DEQ forward and backward passes instead of full-batch measurementsRED (DEQ) · IDT, 20 dB input SNRmeasurement memory per iteration: 3.56 GB -> 0.71 GBImproved
Increase the ODER measurement minibatch from 100 to 250 (ablation)ODER · IDT, 15 dB input SNRSNR (dB): 40.28 -> 40.57Improved