Measured effects reported in the paper

What was changedWhereMeasuredEffect
use full covariance instead of diagonal covariance (ablation)equivariant UQ model · ModelNet40 inertiaMAE: 0.092 -> 0.078Improved
use full covariance instead of diagonal UQ (ablation)equivariant UQ model · Materials Project dielectricMAE: 2.25 -> 1.55Improved
train with LE-ESO (Laplace) instead of Gaussian NLL (ablation)matrix-exp covariance head · Materials Project dielectricMAE: 1.78 -> 1.55Improved
train with LE-ESO instead of Energy Score (ablation)matrix-exp covariance head · Materials Project dielectricMAE: 1.64 -> 1.55Improved
train with LE-ESO instead of Gaussian NLL (ablation)matrix-exp covariance head · Materials Project dielectricMACE: 0.092 -> 0.049Improved
use matrix exponential head instead of Cholesky covariance head (ablation)equivariant mean model · ModelNet40 inertiacovariance equivariance error: 4.30e-1 -> 2.75e-7Improved
use matrix exponential instead of direct equivariant regression of covariance (ablation)equivariant covariance head · ModelNet40 inertiaSPD validityImproved
apply post-hoc temperature scaling (T about 0.05) (ablation)Ours (Full Cov.) · Materials Project dielectricEnergy Score: 0.87 -> 0.66Improved
rank by lambda_max(Sigma) instead of Trace(Sigma) for risk-coverage (ablation)predicted covariance · Materials Project, 90% coverageretained-set MAE improvement: 0.8% -> 3.1%Improved
joint training without gradient detachment instead of detached UQ gradients (ablation)LE-ESO training · Materials Project dielectricMAE: MAE difference <0.02No clear effect
set LE-ESO weight alpha=1 versus smaller values (ablation)LE-ESO · validation sweepvalidation MAEImproved
add anisotropic jitter to eigenvalues for gradient stability (ablation)spectral decomposition · Materials Project dielectriccalibration (MACE): MACE change <1e-4No clear effect