Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add semantic consistency loss L_Con to the tokenizer (ablation) | SIGMA-PPG (30M) · Systolic BP, linear probing | MAE: 15.62 -> 13.07 | Improved |
| add semantic consistency loss L_Con to the tokenizer (ablation) | SIGMA-PPG (30M) · Heart rate, linear probing | MAE: 9.21 -> 5.83 | Improved |
| add semantic consistency loss L_Con to the tokenizer (ablation) | SIGMA-PPG · full fine-tuning, all downstream tasks | MAE and AUC | Improved |
| replace random masking with prior-guided adversarial masking (ablation) | SIGMA-PPG · regression and classification downstream tasks | MAE and AUC | Improved |
| use unconstrained adversarial Teacher (no statistical prior) instead of prior-guided (ablation) | SIGMA-PPG · pre-training masking | representation quality | Hurt |
| use static prior-based masking instead of adaptive Teacher (ablation) | SIGMA-PPG · pre-training masking | representation quality | Hurt |
| use standard random masking (ablation) | SIGMA-PPG · pre-training masking | representation quality | Hurt |
| use generative masked pretraining vs best contrastive baseline | SIGMA-PPG (30M) · SpO2, BIDMC, full fine-tuning | MAE: 1.265 -> 0.1457 | Improved |
| scale SIGMA-PPG from 5M to 30M parameters (ablation) | SIGMA-PPG · full fine-tuning average | AUC: 0.8596 -> 0.9082 | Improved |
| use SIGMA-PPG instead of Pulse-PPG under linear probing on classification | SIGMA-PPG (30M) · linear probing classification average | AUC: 0.8820 -> 0.8510 | Hurt |
| use SIGMA-PPG instead of Pulse-PPG under linear probing on regression | SIGMA-PPG (30M) · linear probing regression average | MAE: 6.781 -> 6.636 | Improved |
| use SIGMA-PPG (30M) instead of Pulse-PPG for compute | SIGMA-PPG (30M) · Computational cost | FLOPs: 27.11 -> 2.56 GMac | Improved |
Closest papers by meaning
- PaPaGei: Open Foundation Models for Optical Physiological Signals (ICLR 2025 · similarity 0.88)
- Constraint Latent Space Matters: An Anti-anomalous Waveform Transformation Solution from Photoplethysmography to Arterial Blood Pressure (AAAI 2024 · similarity 0.85)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.84)
- Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios (CVPR 2025 · similarity 0.84)
- RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement (AAAI 2025 · similarity 0.83)
- FactorizePhys: Matrix Factorization for Multidimensional Attention in Remote Physiological Sensing (NeurIPS 2024 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.