Research map / Vision-language and multimodal / Human and embodied modeling
ProConMV: Provenance-Enabled Conceptual Framework for Interpretable Multi-View Diabetic Retinopathy Diagnosis
Xiaoling Luo, Shuo Yang, Qihao Xu, Jiansong Zhang, Zhuoqin Yang, Zhihui Lai, Linlin Shen, Chengliang Liu
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add dual-uncertainty multi-view fusion (DU-MVFD) (ablation) | ProConMV · MFIDDR (four views) ablation | grading accuracy: 86.23 -> 86.75 | Improved |
| add dual-uncertainty multi-view fusion (DU-MVFD) (ablation) | ProConMV · MFIDDR (four views) ablation | grading kappa: 75.23 -> 76.05 | Improved |
| add text and VT-RWKV concept integration (ablation) | ProConMV · MFIDDR (four views) ablation | grading accuracy: 85.68 -> 86.75 | Improved |
| add Hilbert-RWKV backbone (ablation) | ProConMV · MFIDDR (four views) ablation | grading accuracy: 85.72 -> 86.75 | Improved |
| add lesion masks as input (ablation) | ProConMV · MFIDDR (four views) ablation | grading accuracy: 85.21 -> 86.75 | Improved |
| add Hilbert-RWKV backbone to MVCBM baseline (ablation) | MVCBM · MFIDDR (four views) ablation | concept F1: 59.10 -> 63.87 | Improved |
| add DU-MVFD alone to MVCBM baseline (ablation) | MVCBM · MFIDDR (four views) ablation | concept AUPR: 61.56 -> 60.87 | Hurt |
| use Hilbert-RWKV instead of ResNet-50 backbone (ablation) | ProConMV · MFIDDR (four views) | concept AUPR: 67.71 -> 72.26 | Improved |
| use Hilbert-RWKV instead of ResNet-50 backbone (ablation) | ProConMV · MFIDDR (four views) | parameters and inference time: 25.26M -> 6.70M; 10.16ms -> 8.77ms | Improved |
| use Hilbert-RWKV instead of VMamba (ablation) | ProConMV · MFIDDR (four views) | grading accuracy: 83.03 -> 86.75 | Improved |
| use Hilbert scan instead of zigzag scan (ablation) | Hilbert-RWKV · MFIDDR (four views) (scan strategy) | concept F1: 63.89 -> 68.92 | Improved |
| use Hilbert scan instead of sweep scan (ablation) | Hilbert-RWKV · MFIDDR (four views) (scan strategy) | grading accuracy: 86.29 -> 86.75 | Improved |
Closest papers by meaning
- Like an Ophthalmologist: Dynamic Selection Driven Multi-View Learning for Diabetic Retinopathy Grading (AAAI 2025 · similarity 0.87)
- FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs (NeurIPS 2026 · similarity 0.86)
- DrVD-Bench: Do Vision-Language Models Reason Like Human Doctors in Medical Image Diagnosis? (NeurIPS 2025 · similarity 0.85)
- Domain Adaptive Diabetic Retinopathy Grading with Model Absence and Flowing Data (CVPR 2025 · similarity 0.84)
- HACDR-Net: Heterogeneous-Aware Convolutional Network for Diabetic Retinopathy Multi-Lesion Segmentation (AAAI 2024 · similarity 0.84)
- Visual and Domain Knowledge for Professional-level Graph-of-Thought Medical Reasoning (ICML 2025 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
