Staged and Physics-Grounded Learning Framework with Hyperintensity Prior for Pre-Contrast MRI Synthesis

ICML 2025 · Image generation › Autoregressive and latent generation · approach: Retrieval and matching with generative features

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes SPHERE, a two-stage physics-grounded framework that segments contrast uptake with a hyperintensity prior and then inpaints Pre-Contrast MRI from Post-Contrast scans, with an artifact-correction variant SPHERE-Art.

Problem

Pre-Contrast MRI is often missing or corrupted, yet it is needed as a reference for quantitative and comparative contrast-enhanced MRI analysis; direct Post-to-Pre image-to-image synthesis produces blurry or distorted contrast details.

Approach

Derive from the SPGR signal model that Pre-Contrast signal can be expressed via a learnable contrast uptake mask, then decompose synthesis into a segmentation stage (NestedUNet plus a soft-threshold hyperintensity prior) and an "inpainting+" stage that reconstructs the Pre-Contrast image using Post-Contrast and the mask.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use dual-stage learning instead of a single-stage model (ablation)SPHERE · Site APSNR: 34.5522 -> 36.8244Helped
add the hyperintensity prior (ablation)SPHERE · Site APSNR: 35.7608 -> 36.8244Helped
add the segmentation branch (ablation)SPHERE · Site APSNR: 36.3764 -> 36.8244Helped
add the autoencoder module (ablation)SPHERE · Site APSNR: 36.6764 -> 36.8244Helped
vary brightness threshold τ from 0.06 to 0.14 (ablation)SPHERE · Site APSNR: 35.7835; 36.8841; 36.8244; 36.8759; 36.7256No clear effect

Surprising findings

Limitations

Experimental setup

Datasets: Site A private MPRAGE cohort (126 cases) Site B private MPRAGE cohort (159 cases) spine fine-tuning set (5 patients) breast fine-tuning set (3 cases)

Benchmarks: Site A test set (13 cases) Site B test set (10 cases) motion artifact removal test set low-dose simulation spine and breast transfer tasks

Metrics: PSNR SSIM CNR LPIPS CFS GMSD IRC EIS RMSE NPS

Baselines: UNet Att-UNet NestedUNet SwinIR UKAN MambaIR BICEPS R2-AttUNet

Builds on: NestedUNet BICEPS subtraction imaging pix2pix-style GAN loss