Distribution-aware Fairness Learning in Medical Image Segmentation From A Control-Theoretic Perspective

ICML 2025 · Label-efficient and robust learning › Recognition and long-tail · approach: Data augmentation and generalization bias · 0 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes distribution-aware Mixture of Experts (dMoE), a control-theory-inspired MoE whose routers are conditioned on demographic/clinical attributes, to improve fairness in medical image segmentation across 2D and 3D benchmarks.

Problem

Fairness in medical image segmentation is harmed by imbalanced clinical data across demographic attributes (age, sex, race) and clinical factors (disease severity such as T-stage), causing underperformance on minority subgroups.

Approach

Reinterprets MoE as a feedback control mechanism and adds attribute-specific routers (shared experts, separate gating per attribute flag), framed as mode-switching optimal control so the network adapts its parameter selection to distributional attributes.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace the default MoE router with a distribution-aware routerTransUNet · Harvard-FairSeg rimES-Dice: 0.733 (0.713-0.752) -> 0.743 (0.723-0.763)Helped
replace the default MoE router with a distribution-aware routerTransUNet · Harvard-FairSeg cupES-Dice: 0.830 (0.809-0.847) -> 0.832 (0.810-0.853)Helped
replace the default MoE router with a distribution-aware routerTransUNet · HAM10000ES-Dice: 0.796 (0.741-0.844) -> 0.801 (0.745-0.847)Helped
add dMoE to the 3D ResUNet3D ResUNet · Radiotherapy target (T-stage)ES-Dice: 0.487 (0.447-0.529) -> 0.499 (0.469-0.531)Helped
place dMoE in the decoder only rather than the encoder only (ablation)TransUNet dMoE · HAM10000ES-Dice: 0.841 -> 0.840No clear effect
place dMoE in both encoder and decoder rather than the encoder only (ablation)TransUNet dMoE · HAM10000ES-Dice: 0.841 -> 0.842No clear effect
share dMoE parameters across layers (ablation)TransUNet dMoE · HAM10000ES-Dice: 0.812 -> 0.841Helped
remove mode-switching while retaining feedback control (ablation)TransUNet dMoE · HAM10000ES-Dice: 0.836 -> 0.841Helped
add feedback and mode-switching control (ablation)TransUNet dMoE · HAM10000ES-Dice: 0.826 -> 0.841Helped
place dMoE in the decoder only rather than the encoder only (ablation)3D ResUNet dMoE · Radiotherapy target (T-stage)ES-Dice: 0.546 -> 0.569Mixed
place dMoE in both encoder and decoder rather than the encoder only (ablation)3D ResUNet dMoE · Radiotherapy target (T-stage)ES-Dice: 0.546 -> 0.543No clear effect
use layer-wise rather than shared dMoE parameters (ablation)3D ResUNet dMoE · Radiotherapy target (T-stage)ES-Dice: 0.546 -> 0.546No clear effect

Surprising findings

Limitations

Experimental setup

Datasets: Harvard-FairSeg HAM10000 in-house radiotherapy target dataset (prostate CT)

Benchmarks: Harvard-FairSeg HAM10000 in-house radiotherapy target dataset

Metrics: Dice IoU ES-Dice ES-IoU worst-group accuracy

Baselines: TransUNet ADV DRO FEBS FairDiff MoE 3D ResUNet

Builds on: Mixture of Experts Noisy Top-K Gating TransUNet 3D ResUNet