atlas

Research map / 3D vision / Depth and stereo

iToF-flow-based High Frame Rate Depth Imaging

CVPR 2024 · 3D vision › Depth and stereo · approach: Depth from light field and defocus · 4 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes iToF-flow, decomposing iToF measurement variation into cross-mode (LLT-based) and uni-mode (photometric correction) flows to enable high-frame-rate, motion-robust depth extraction from alternating 4-phase iToF measurements.

Problem

Depth estimation with indirect time-of-flight (iToF) cameras degrades in dynamic scenes because the four phase measurements are captured at different times, causing motion artifacts and limiting depth frame rate.

Approach

Models iToF measurement variation as cross-mode flow (a motion-insensitive local linear transform between phase modes plus optical flow for pixel shift) and uni-mode flow (depth-dependent photometric residual derived from a first-order Taylor expansion), implemented as LCTM and UPCM modules that propagate absent phase measurements to each time instant.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use iToF flow-based depth extraction instead of FFNiToF depth reconstruction · iToF test setMAEd (cm): 7.58 -> 4.72Helped
Use iToF flow-based depth extraction instead of FFNiToF measurement reconstruction · iToF test setMAEp: 3.79 -> 1.51Helped
Use iToF flow-based depth extraction instead of FFNiToF depth reconstruction · iToF test setTime (s): 0.32 -> 0.081Hurt
Add SFE to LMM (ablation)LMM-based cross-mode transfer · iToF test setMAEd (cm): 6.24 -> 5.83Helped
Add UPCM to LMM (ablation)LMM-based cross-mode transfer · iToF test setMAEd (cm): 6.24 -> 5.51Helped
Add UPCM to LMM + SFE (ablation)iToF flow depth extraction network · iToF test setMAEd (cm): 5.83 -> 4.72Helped
Add LMM to SFE + UPCM (ablation)iToF flow depth extraction network · iToF test setMAEd (cm): 5.51 -> 4.72Helped

Surprising findings

Limitations

Experimental setup

Datasets: CB-ToF CB-ToF-Extension Matterport3D YCB-V

Benchmarks: iToF synthetic dynamic scenes (20MHz and 30MHz) real-world QVGA Sony IMX518 captures at 30MHz

Metrics: MAE of depth (cm) MAE of four-mode measurements mask rate parameters (M) runtime (s)

Baselines: SDE RAFT FFN MOM

Builds on: FFN MOM RAFT EDB-based optical flow

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy