Proposes ToNNO, which trains a 2D slice classifier on volume-level labels and reconstructs a 3D segmentation heatmap via inverse Radon transform, plus Averaged and Tomographic CAM variants, for weakly supervised 3D medical image segmentation.
Problem
Weakly supervised segmentation of 3D medical images using only image-level (volume-level) presence/absence labels for regions such as tumours or lesions, where existing methods mostly rely on 2D CAM and yield low-resolution heatmaps.
Approach
Train a 2D encoder on randomly oriented slices of 3D volumes with volume-level labels, then replace the sum in the Radon transform with the network output and apply the inverse 3D-2D Radon transform (filtered backprojection) to reconstruct a 3D heatmap; also average CAM maps across many rotations, with a second-derivative filtering step (Tomographic CAM) to keep deep-layer maps sharp.
Key results
- Tomographic LayerCAM achieves the best F1-score, with an average improvement of 0.14 over LayerCAM across the four datasets.
- On Multiple Sclerosis, ToNNO improves Dice over LayerCAM from 0.41 to 0.53 (+0.12).
- On Duke, ToNNO raises balanced accuracy from 0.58 to 0.79 and F1 from 0.24 to 0.51 relative to LayerCAM.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Use ToNNO instead of LayerCAM | ResNet-10-T, frozen batch norm · Multiple Sclerosis | F1-score: 0.73 -> 0.82 | Helped |
| Use ToNNO instead of LayerCAM | ResNet-10-T, frozen batch norm · AutoPET | F1-score: 0.35 -> 0.39 | Helped |
| Use ToNNO instead of LayerCAM | ResNet-10-T, frozen batch norm · MosMed | F1-score: 0.39 -> 0.50 | Helped |
| Use ToNNO instead of LayerCAM | ResNet-10-T, frozen batch norm · Duke | F1-score: 0.24 -> 0.51 | Helped |
| Apply tomographic reconstruction to LayerCAM heatmaps instead of standard LayerCAM | ResNet-10-T, frozen batch norm · AutoPET | F1-score: 0.35 -> 0.49 | Helped |
| Apply tomographic reconstruction to LayerCAM heatmaps instead of standard LayerCAM | ResNet-10-T, frozen batch norm · MosMed | F1-score: 0.39 -> 0.55 | Helped |
| Apply tomographic reconstruction to LayerCAM heatmaps instead of standard LayerCAM | ResNet-10-T, frozen batch norm · Multiple Sclerosis | F1-score: 0.73 -> 0.84 | Helped |
| Apply tomographic reconstruction to LayerCAM heatmaps instead of standard LayerCAM | ResNet-10-T, frozen batch norm · Duke | F1-score: 0.24 -> 0.51 | Helped |
| Add pretrained weights (ablation) | ResNet-10-T · All four datasets | F1-score: 0.28 -> 0.55 | Helped |
| Freeze batch-normalization layers rather than use vanilla batch normalization (ablation) | ResNet-10-T · All four datasets | F1-score: 0.48 -> 0.55 | Helped |
| Replace batch normalization with group normalization (ablation) | ResNet-10-T · All four datasets | F1-score: 0.48 -> 0.54 | Helped |
| Use ResNet-50 with group normalization instead of ResNet-10-T with frozen batch normalization (ablation) | ToNNO classifier · All four datasets | F1-score: 0.55 -> 0.56 | No clear effect |
Surprising findings
- Batch normalization harms the classifier for tomographic reconstruction; frozen BN or group norm works better, and a ResNet-10-T with random initialization performs much worse.
Limitations
- Reconstruction is slower than slice-wise CAM methods, requiring many inferences per volume.
- Tomographic and Averaged CAM are not perfect generalizations of ToNNO; deep-layer CAM maps remain blurry in intermediate cases.
- Tomographic reconstructions are too sharp for large lesions, leading to undersegmentation on MosMed.
Experimental setup
Datasets: Multiple Sclerosis brain MRI (private) AutoPET-II MosMedData COVID-19 Duke breast cancer MRI
Benchmarks: Multiple Sclerosis AutoPET-II MosMedData COVID-19 Duke breast cancer MRI
Metrics: precision recall F1-score Dice MaxIoU balanced accuracy
Baselines: GradCAM LayerCAM Averaged LayerCAM
Builds on: GradCAM LayerCAM ResNet
Closest papers by meaning
- Integrating Deep Metric Learning with Coreset for Active Learning in 3D Segmentation (NeurIPS 2024 · similarity 0.86)
- SGTC: Semantic-Guided Triplet Co-training for Sparsely Annotated Semi-Supervised Medical Image Segmentation (AAAI 2025 · similarity 0.85)
- Upping the Game: How 2D U-Net Skip Connections Flip 3D Segmentation (NeurIPS 2024 · similarity 0.84)
- EffiDec3D: An Optimized Decoder for High-Performance and Efficient 3D Medical Image Segmentation (CVPR 2025 · similarity 0.84)
- Revisiting MAE Pre-training for 3D Medical Image Segmentation (CVPR 2025 · similarity 0.84)
- UniPro: Unified Multi-Mode Medical Image Segmentation from 2D Images to 3D Volumes via Propagation (NeurIPS 2026 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.