Structure-Aware Sparse-View X-ray 3D Reconstruction

CVPR 2024 · 3D vision › NeRF and radiance fields · approach: Inverse rendering with neural fields · 77 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes SAX-NeRF, a Transformer-based X-ray neural radiodensity field with line-segment self-attention and masked local-global ray sampling, plus a new 15-scene X3D dataset, for sparse-view X-ray novel view synthesis and CT reconstruction.

Problem

Sparse-view X-ray 3D reconstruction (novel view synthesis and CT reconstruction) with NeRF-style methods, which ignore X-ray's attenuation/internal-structure nature and use MLPs and naive pixel-level ray sampling.

Approach

Replace the MLP radiodensity field with a Line Segment-based Transformer that computes self-attention within each segment of an X-ray (linear cost in points), and sample rays with a masked local-global strategy that combines patch-level and pixel-level sampling on foreground regions.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Add LS-MSA to the baseline (ablation)SAX-NeRF · X3D NVS averagePSNR: 37.97 -> 47.95Helped
Add LS-MSA to the baseline (ablation)SAX-NeRF · X3D CT reconstruction averagePSNR: 34.21 -> 36.86Helped
Add MLG sampling to the baseline (ablation)SAX-NeRF · X3D NVS averagePSNR: 37.97 -> 43.51Helped
Add MLG sampling to the baseline (ablation)SAX-NeRF · X3D CT reconstruction averagePSNR: 34.21 -> 35.30Helped
Add LS-MSA and MLG sampling (ablation)SAX-NeRF · X3D NVS averagePSNR: 37.97 -> 51.37Helped
Add LS-MSA and MLG sampling (ablation)SAX-NeRF · X3D CT reconstruction averagePSNR: 34.21 -> 37.25Helped
Set line segment quantity to 20 (ablation)SAX-NeRF · X3D NVS averagePSNR: 51.365 -> 45.776Hurt
Set line segment quantity to 40 (ablation)SAX-NeRF · X3D NVS averagePSNR: 51.365 -> 47.832Hurt
Set line segment quantity to 80 (ablation)SAX-NeRF · X3D NVS averagePSNR: 51.365 -> 50.148Hurt
Set line segment quantity to 320 (ablation)SAX-NeRF · X3D NVS averagePSNR: 51.365 -> 50.620Hurt
Replace LS-MSA with vanilla Transformer G-MSA (ablation)SAX-NeRF · X3D NVS averagePSNR: +5.30 dBHurt
Replace LS-MSA with vanilla Transformer G-MSA (ablation)SAX-NeRF · X3D CT reconstruction averagePSNR: +1.28 dBHurt

Surprising findings

Limitations

Experimental setup

Datasets: X3D LIDC-IDRI MIDA D2VR DeepOrgan VOLVIS open scientific visualization dataset

Benchmarks: X3D

Metrics: PSNR SSIM

Baselines: InTomo NeRF NeAT TensoRF NAF FDK ASD-POCS SART