atlas

Research map / Detection and segmentation / Open-set and few-shot detection

Kandinsky Conformal Prediction: Efficient Calibration of Image Segmentation Algorithms

CVPR 2024 · Detection and segmentation › Open-set and few-shot detection · approach: Amodal and open-world instance segmentation · 12 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes Kandinsky calibration, which clusters spatially similar pixels of a segmentation network and pools their conformal non-conformity scores, giving an intermediate between imagewise and pixelwise conformal calibration that is more data-efficient in low-data regimes.

Problem

Inductive conformal prediction for image segmentation requires many calibration images for pixelwise (conditional) calibration, while imagewise (marginal) calibration is miscalibrated per pixel; calibration is hard when labeled medical data are scarce.

Approach

Cluster pixel locations by similarity of their non-conformity curves (via k-means, genetic-algorithm annuli, or Fourier concentric clustering), pool non-conformity scores within each cluster, and use the cluster-specific quantile curve for prediction sets, exploiting spatial correlation of pixel classifiers.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use pixelwise calibration instead of Kandinsky calibrationU-Net segmentation · MS-COCO-XLmean coverage error: 0.055 vs 0.064Helped
Use Kandinsky calibration instead of pixelwise calibrationU-Net segmentation · MS-COCO-Smean coverage error: 0.131 vs 0.060Helped
Use Kandinsky calibration instead of imagewise calibrationU-Net segmentation · MS-COCO-Smean coverage error: 0.091 vs 0.060Helped
Use Kandinsky calibration instead of pixelwise calibrationU-Net segmentation · Decathlon-Lmean coverage error: 0.217 vs 0.145Helped
Use Kandinsky calibration instead of imagewise calibrationU-Net segmentation · Decathlon-Lmean coverage error: 0.177 vs 0.145Helped
Use Kandinsky calibration instead of pixelwise calibrationU-Net segmentation · Decathlon-Smean coverage error: 0.249 vs 0.152Helped
Use Kandinsky calibration instead of imagewise calibrationU-Net segmentation · Decathlon-Smean coverage error: 0.175 vs 0.152Helped
Use GenAnn or FCC-Ann rather than K-means clusteringKandinsky calibration · MS-COCO-Smean coverage error: 0.086 vs 0.068; 0.086 vs 0.060Helped
Use k-means clustering rather than GenAnn or FCC-AnnKandinsky calibration · Decathlon-Lmean coverage error: 0.145 vs 0.150; 0.145 vs 0.152Helped
Use GenAnn clustering rather than K-means or FCC-AnnKandinsky calibration · Decathlon-Smean coverage error: 0.152 vs 0.168; 0.152 vs 0.165Helped

Surprising findings

Limitations

Experimental setup

Datasets: MS-COCO Medical Decathlon (Pancreas)

Benchmarks: MS-COCO Medical Decathlon Pancreas

Metrics: coverage error (CE20) mean coverage error with quantiles

Baselines: pixelwise calibration imagewise calibration k-means clustering calibration

Builds on: inductive conformal prediction differential evolution k-means clustering

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy