Research map / Label-efficient and robust learning / Recognition and long-tail
Digital Voicing of Silent Speech
Read the paperPlace an idea next to itCheck your own paper ↗
12measured effects
11improved
1hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| train on silent EMG with audio targets transferred from vocalized recordings | direct transfer baseline · Closed-vocabulary silent EMG (human transcription) | WER (%): 64.6 -> 3.6 | Improved |
| train on silent EMG with transferred audio targets | direct transfer baseline · Open-vocabulary silent EMG (ASR transcription) | WER (%): 88.0 -> 68.0 | Improved |
| same, human transcription | direct transfer without throat electrode · Open-vocabulary silent EMG (human transcription) | WER (%): 95.1 -> 74.8 | Improved |
| remove the throat electrode | direct transfer baseline · Closed-vocabulary silent EMG (human transcription) | WER (%): 88.8 -> 64.6 | Improved |
| remove the throat electrode | direct transfer baseline · Open-vocabulary silent EMG (ASR transcription) | WER (%): 91.2 -> 88.0 | Improved |
| add CCA-based alignment cost (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 69.8 -> 68.0 | Improved |
| add predicted-audio alignment refinement (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 76.5 -> 68.0 | Improved |
| add non-parallel vocalized data (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 71.6 -> 68.0 | Improved |
| remove equal amount of data proportionally across parallel and non-parallel (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 68.0 -> 76 | Hurt |
| use all eight electrodes instead of best four-electrode subset (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 76.8 -> 68.0 | Improved |
| keep electrodes 5, 7, 8 (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%): 75.3 -> 68.0 | Improved |
| increase training data from 10% toward 100% (ablation) | our model · Open-vocabulary silent EMG (ASR transcription) | WER (%) | Improved |
Closest papers by meaning
- LipVoicer: Generating Speech from Silent Videos Guided by Lip Reading (ICLR 2024 · similarity 0.83)
- emg2qwerty: A Large Dataset with Baselines for Touch Typing using Surface Electromyography (NeurIPS 2024 · similarity 0.83)
- From Faces to Voices: Learning Hierarchical Representations for High-quality Video-to-Speech (CVPR 2025 · similarity 0.82)
- Let There Be Sound: Reconstructing High Quality Speech from Silent Videos (AAAI 2024 · similarity 0.82)
- EMAGE: Towards Unified Holistic Co-Speech Gesture Generation via Expressive Masked Audio Gesture Modeling (CVPR 2024 · similarity 0.82)
- Time-Masked Transformers with Lightweight Test-Time Adaptation for Neural Speech Decoding (NeurIPS 2025 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.