Research map / Label-efficient and robust learning / Recognition and long-tail
Combining Automatic Labelers and Expert Annotations for Accurate Radiology Report Labeling Using BERT
Akshay Smit, Saahil Jain, Pranav Rajpurkar, Anuj Pareek, Andrew Y. Ng, Matthew P. Lungren
Stanford University
Read the paperPlace an idea next to itCheck your own paper ↗
11measured effects
8improved
2hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| fine-tune all BERT layers instead of freezing them (T-rad vs T.cls-rad) (ablation) | BERT-base on radiologist labels · MIMIC-CXR test set | average weighted-F1: 0.286 -> 0.705 | Improved |
| pre-train on automatic CheXpert labels (T-auto vs T-rad) (ablation) | BERT-base · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.755 | Improved |
| first train on automatic labels then fine-tune on radiologist labels (hybrid) (ablation) | BERT-base · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.775 | Improved |
| initialize with BioBERT (ablation) | T-rad · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.616 | Hurt |
| initialize with Clinical BioBERT (ablation) | T-rad · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.677 | Hurt |
| initialize with BlueBERT (ablation) | T-rad · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.741 | Improved |
| add backtranslation augmentation (ablation) | T-rad · MIMIC-CXR test set | average weighted-F1: 0.705 -> 0.729 | Improved |
| add backtranslation augmentation (ablation) | T-hybrid · MIMIC-CXR test set | average weighted-F1: 0.775 -> 0.795 | Improved |
| add backtranslation augmentation (ablation) | Tblue-rad · MIMIC-CXR test set | average weighted-F1: 0.741 -> 0.770 | Improved |
| combine BlueBERT, hybrid training and backtranslation (CheXbert vs CheXpert) | CheXpert labeler · MIMIC-CXR test set | average weighted-F1: 0.743 -> 0.798 | Improved |
| CheXbert vs CheXpert on Lung Lesion and Lung Opacity | CheXpert labeler · MIMIC-CXR test set | per-condition F1 difference: -0.019 (Lung Lesion), -0.021 (Lung Opacity) | Mixed |
Closest papers by meaning
- Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards (EMNLP 2022 · similarity 0.88)
- MediVLM: A Vision Language Model for Radiology Report Generation from Medical Images (EMNLP 2025 · similarity 0.87)
- Structuring Radiology Reports: Challenging LLMs with Lightweight Models (EMNLP 2025 · similarity 0.87)
- Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation (AAAI 2022 · similarity 0.87)
- Learning Visual-Semantic Embeddings for Reporting Abnormal Findings on Chest X-rays (EMNLP 2020 · similarity 0.87)
- Instance-level Expert Knowledge and Aggregate Discriminative Attention for Radiology Report Generation (CVPR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
