Research map / Vision-language and multimodal / Human and embodied modeling
Generating Radiology Reports via Memory-driven Transformer
Zhihong Chen, Yan Song, Tsung-Hui Chang, Xiang Wan
The Chinese University of Hong Kong · Shenzhen Research Institute of Big Data
Read the paperPlace an idea next to itCheck your own paper ↗
9measured effects
7improved
2hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MIMIC-CXR leaderboard BLEU-4 0.103 · rank 35 of 36 papers
- IU-Xray leaderboard BLEU-4 0.165 · rank 23 of 26 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add relational memory to Transformer decoder output (BASE+RM) (ablation) | BASE Transformer · IU X-RAY test | BLEU-4: 0.135 -> 0.141 | Improved |
| add MCLN to integrate memory in decoder layers (ablation) | BASE+RM · IU X-RAY test | BLEU-4: 0.141 -> 0.165 | Improved |
| add MCLN to integrate memory in decoder layers (ablation) | BASE+RM · MIMIC-CXR test | BLEU-4: 0.095 -> 0.103 | Improved |
| add relational memory (ablation) | BASE Transformer · MIMIC-CXR test | CE precision: 0.331 -> 0.325 | Hurt |
| add relational memory and MCLN (ablation) | BASE Transformer · MIMIC-CXR test | CE F1: 0.228 -> 0.276 | Improved |
| add relational memory and MCLN (ablation) | BASE Transformer · IU X-RAY test | average NLG improvement: +17.6% vs +12.1% on MIMIC-CXR | Improved |
| raise memory slots from 3 to 4 (ablation) | full model · MIMIC-CXR test | BLEU-1: 0.360 -> 0.354 | Hurt |
| raise memory slots from 1 to 3 (ablation) | full model · MIMIC-CXR test | BLEU-1: 0.350 -> 0.360 | Improved |
| use full model instead of CMAS-RL (reinforcement learning) | previous models · IU X-RAY test | BLEU-4: 0.154 -> 0.165 | Improved |
Closest papers by meaning
- Progressive Transformer-Based Generation of Radiology Reports (EMNLP 2021 · similarity 0.91)
- Learning to Generate Clinically Coherent Chest X-Ray Reports (EMNLP 2020 · similarity 0.90)
- Automatic Radiology Reports Generation via Memory Alignment Network (AAAI 2024 · similarity 0.88)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.88)
- AHIVE: Anatomy-aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval (CVPR 2024 · similarity 0.88)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
