Research map / Image generation / Text-to-image diffusion
Progressive Transformer-Based Generation of Radiology Reports
Farhad Nooralahzadeh, Nicolas Perez Gonzalez, Thomas Frauenfelder, Koji Fujimoto, Michael Krauthammer
Kyoto University
Read the paperPlace an idea next to itCheck your own paper ↗
11measured effects
8improved
3hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MIMIC-CXR leaderboard BLEU-4 0.107 · rank 31 of 36 papers
- IU-Xray leaderboard BLEU-4 0.173 · rank 18 of 26 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Add progressive (image-to-concepts-to-text) generation | M2 Tr. · IU X-Ray test | BLEU-1: 0.475 -> 0.486 | Improved |
| Add progressive generation | M2 Tr. · IU X-Ray test | ROUGE-L: 0.373 -> 0.390 | Improved |
| Add progressive generation | M2 Tr. · IU X-Ray test | BLEU-4: 0.180 -> 0.173 | Hurt |
| Add progressive generation | M2 Tr. · MIMIC-CXR test | clinical efficacy F1: 0.276 -> 0.308 | Improved |
| Add progressive generation | M2 Tr. · MIMIC-CXR test | clinical efficacy recall: 0.241 -> 0.428 | Improved |
| Add progressive generation | M2 Tr. · MIMIC-CXR test | clinical efficacy precision: 0.324 -> 0.240 | Hurt |
| Add progressive generation | M2 Tr. · MIMIC-CXR test | BLEU-1: 0.361 -> 0.378 | Improved |
| Use memory-augmented meshed transformer (M2 Tr.) instead of vanilla Transformer in ViLM | Transformer · IU X-Ray test | BLEU-1: 0.388 -> 0.475 | Improved |
| Use M2 Tr. Progressive instead of R2Gen | R2Gen · IU X-Ray test | average of NLG metrics: +1.23% | Improved |
| Use M2 Tr. Progressive instead of R2Gen | R2Gen · MIMIC-CXR test | clinical efficacy F1: +3.2% | Improved |
| Use M2 Tr. Progressive instead of R2Gen | R2Gen · MIMIC-CXR test | ROUGE-L / precision: 0.277 -> 0.272 (ROUGE-L); 0.333 -> 0.240 (precision) | Hurt |
Closest papers by meaning
- Generating Radiology Reports via Memory-driven Transformer (EMNLP 2020 · similarity 0.91)
- Learning to Generate Clinically Coherent Chest X-Ray Reports (EMNLP 2020 · similarity 0.90)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.89)
- CURE: Curriculum-guided Multi-task Training for Reliable Anatomy Grounded Report Generation (CVPR 2026 · similarity 0.87)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.86)
- AHIVE: Anatomy-aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval (CVPR 2024 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.