atlas

Research map / 3D vision / Human pose estimation

Attention Mechanism Exploits Temporal Contexts: Real-Time 3D Human Pose Reconstruction

CVPR 2020 · 3D vision › Human pose estimation · approach: Monocular 2D-to-3D pose lifting · 275 citations (OpenAlex)

Check your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Add the attention-based temporal convolution modelVideo-based 3D pose estimation with CPN 2D input · Human3.6M Protocol#1MPJPE (mm): 46.8 -> 45.1Helped
Use ground-truth rather than detected 2D joints as inputOurs (n=243) · Human3.6M Protocol#1MPJPE (mm): 45.1 -> 34.7Helped
Add the attention-based temporal convolution modelVideo-based 3D pose estimation with CPN 2D input · Human3.6M Protocol#2P-MPJPE (mm): 36.5 -> 35.6Helped
Add the proposed modelVideo-based 3D pose estimation · HumanEva Protocol#2P-MPJPE (mm): 15.8 -> 15.4Helped
Combine attention and multi-scale dilation rather than using either alone (ablation)Proposed pose model · Human3.6M Protocol#1, CPN 2D input, n=243MPJPE (mm): 46.3 -> 45.1; 45.7 -> 45.1Helped
Combine attention and multi-scale dilation rather than using either alone (ablation)Proposed pose model · Human3.6M Protocol#1, ground-truth 2D input, n=243MPJPE (mm): 35.5 -> 34.7; 35.3 -> 34.7Helped
Use kernel attention with M=3 instead of M=2 or M=4 (ablation)Kernel attention module · Human3.6M Protocol#1MPJPE (mm): 37.1 -> 35.5; 38.0 -> 35.5Helped
Set kernel-attention groups to G=2 rather than G=8 (ablation)Kernel attention module · Human3.6M Protocol#1MPJPE (mm): 35.5 -> 35.3Helped
Set kernel-attention groups to G=1 or G=16 rather than G=8 (ablation)Kernel attention module · Human3.6M Protocol#1MPJPE (mm): 35.5 -> 37.4; 35.5 -> 37.3Hurt
Vary kernel-attention reduction dimension from r=128 (ablation)Kernel attention module · Human3.6M Protocol#1MPJPE (mm): 35.5 -> 35.9; 35.5 -> 36.2Hurt
Increase receptive field from n=27 to n=147 in the tested shallow configuration (ablation)Proposed pose model · Human3.6M Protocol#1MPJPE (mm): 40.6 -> 36.8Helped
Increase receptive field to n=1029 instead of using n=243 (ablation)Proposed pose model · Human3.6M Protocol#1MPJPE (mm): 35.5 -> 37.0Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy