Research map / Large language models / Language, safety and interpretability
Readability Controllable Biomedical Document Summarization
Zheheng Luo, Qianqian Xie, Sophia Ananiadou
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use multi-heads abstractive control (MH Abs) instead of control prompts (ablation) | LED-base · PLOS test, plain language summary | ROUGE-1: 45.69 -> 47.31 | Improved |
| use multi-heads extractive instead of control prompts extractive (ablation) | LED-base · PLOS test, technical summary | ROUGE-1: 49.52 -> 49.17 | No clear effect |
| use abstractive instead of extractive models for plain language summaries | LED-base · PLOS test, plain language summary | ROUGE-1: 45.40 -> 47.31 | Improved |
| apply readability control techniques to generation | MH Abs · PLOS test | RNPTC (plain vs technical): 2.41 tech vs 2.35 plain (targets 2.57 vs 2.41) | Mixed |
| use traditional readability formulas (FKG, CLI, ARI) to tell plain from technical summaries | generated summaries · PLOS test | FKG: 14.25 tech vs 14.75 plain (MH Abs) | No clear effect |
| use multi-heads abstractive instead of control prompts abstractive (ablation) | LED-base · PLOS 4-gram overlap | n-gram overlap fraction: 0.47 -> 0.29 | Improved |
| use extractive instead of abstractive generation | LED-base · PLOS 4-gram overlap | n-gram overlap fraction: 0.29 -> 0.72 (MH) / 0.80 (CP) | Hurt |
| generate summaries with control instead of human targets | MH Abs · PLOS 4-gram overlap | n-gram overlap fraction: 0.08 (targets) vs 0.29 | Hurt |
| generated summaries replace target summaries (laypeople readability gap) | MH Abs · human evaluation (laypeople) | readability rating: gap 4.43-3.37 (targets) -> 3.90-3.83 (generated) | Hurt |
| generated summaries replace target summaries on relevance, coherence, grammar | MH Abs · human evaluation | coherence: 4.62 -> 4.01 (tech) | Hurt |
Closest papers by meaning
- Automated Lay Language Summarization of Biomedical Scientific Reviews (AAAI 2021 · similarity 0.90)
- Generating Summaries with Controllable Readability Levels (EMNLP 2023 · similarity 0.90)
- Improving Biomedical Abstractive Summarisation with Knowledge Aggregation from Citation Papers (EMNLP 2023 · similarity 0.87)
- Understanding Faithfulness and Reasoning of Large Language Models on Plain Biomedical Summaries (EMNLP 2024 · similarity 0.87)
- FaMeSumm: Investigating and Improving Faithfulness of Medical Summarization (EMNLP 2023 · similarity 0.86)
- Evaluating the Evaluators: Are readability metrics good measures of readability? (EMNLP 2025 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
