Research map / Time series / Foundation models for time series
Factual Accuracy is not Enough: Planning Consistent Description Order for Radiology Report Generation
Toru Nishino, Yasuhide Miura, Tomoki Taniguchi, Tomoko Ohkuma, Yuki Suzuki, Shoji Kido, Noriyuki Tomiyama
Fujifilm Corporation · Osaka University Graduate School of Medicine
Read the paperPlace an idea next to itCheck your own paper ↗
12measured effects
7improved
1no clear effect
4hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add CoPlan (RL+BS, order reconstructor) to planning model | Planning (T5 + LSTM planner) · JLiverCT | CO: 52.1 -> 54.8 | Improved |
| add CoPlan (RL+BS, order reconstructor) | Planning · JLiverCT | factual accuracy: 82.1 -> 83.8 | Improved |
| add CoPlan (RL+BS, fact reconstructor) | T5-base · MIMIC-CXR | factual accuracy: 92.2 -> 97.6 | Improved |
| add CoPlan (RL+BS, fact reconstructor) | T5-base · MIMIC-CXR | CO: 34.3 -> 47.7 | Improved |
| add CoPlan (RL+BS, fact reconstructor) | T5-base · MIMIC-CXR | BLEU4: 17.3 -> 16.8 | Hurt |
| use factual reconstructor instead of order reconstructor for RL (ablation) | CoPlan(RL) · JLiverCT | CO: 52.7 -> 49.2 | Hurt |
| use factual reward RL (ablation) | Planning · JLiverCT | factual accuracy: 82.1 -> 81.9 | No clear effect |
| add factual-reward RL when inference constraints are removed (ablation) | Planning · JLiverCT | factual accuracy: 70.8 -> 72.1 | Improved |
| add beam-search coordination with fact reconstructor (ablation) | Planning · JLiverCT | CO: 52.1 -> 46.9 | Hurt |
| use CoPlan with 4-class IC instead of T5-base baseline | E2E system · MIMIC-CXR | clinical Micro-F: 49.5 -> 58.6 | Improved |
| add CoPlan | D2T system · MIMIC-CXR human eval | fluency: 4.85 -> 4.79 | Hurt |
| add CoPlan | T5-Japanese-base · JLiverCT human eval | content order: 61.6 -> 68.9 | Improved |
Closest papers by meaning
- Look Before You Leap: Self-Evolving Clinical Reasoning with Psychometric Preference Optimization for Radiology Report Generation (NeurIPS 2026 · similarity 0.88)
- ConDistill: Asymmetric Context Self-Distillation for Radiology Report Generation (EMNLP 2026 · similarity 0.87)
- RECAP: Towards Precise Radiology Report Generation via Dynamic Disease Progression Reasoning (EMNLP 2023 · similarity 0.87)
- CURE: Curriculum-guided Multi-task Training for Reliable Anatomy Grounded Report Generation (CVPR 2026 · similarity 0.86)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.86)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
