Research map / Large language models / Language, safety and interpretability
BioDEX: Large-Scale Biomedical Adverse Drug Event Extraction for Real-World Pharmacovigilance
Karel D'Oosterlinck, François Remy, Johannes Deleu, Thomas Demeester, Chris Develder, Klim Zaporojets, Aneiss Ghodsi, Simon Ellershaw, Jack Collins, Christopher Potts
Stanford University · Aarhus University · Ghent University
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| fine-tune FLAN-T5-Large instead of few-shot prompting gpt-4 | gpt-4-0312 few-shot · Report-Extraction validation | REP F1: 51.71 -> 62.28 | Improved |
| fine-tune FLAN-T5-Large instead of few-shot prompting gpt-4 | gpt-4-0312 few-shot · Report-Extraction test | REP F1: 53.11 -> 59.1 | Improved |
| increase source tokens from 1024 to 2048 (target 256) (ablation) | FLAN-T5-Large · Report-Extraction validation | REP F1: 55.88 -> 62.28 | Improved |
| increase source tokens from 512 to 1024 (ablation) | FLAN-T5-Large (target 128 -> 256) · Report-Extraction validation | REP F1: 50.92 -> 55.88 | Improved |
| larger model FLAN-T5-XL instead of Large at 1024 source tokens (ablation) | FLAN-T5 · Report-Extraction validation | REP F1: 55.88 -> 58.32 | Improved |
| target tokens 256 instead of 128 (2048 source) (ablation) | FLAN-T5-Large · Report-Extraction validation | REP F1: 61.39 -> 62.28 | Improved |
| beam search (width 8) instead of greedy decoding (ablation) | FLAN-T5-Large · Report-Extraction | REP F1 | No clear effect |
| extend gpt-4 context beyond 4096 tokens with more demos or paper tokens (ablation) | gpt-4-0312 · Report-Extraction validation | REP F1: 51.71 -> 49.69 / 48.00 | No clear effect |
| 7 demos vs 8 demos (ablation) | text-davinci-003 · Report-Extraction validation | REP F1: 50.45 -> 47.16 | Hurt |
| use gpt-3.5-turbo instead of text-davinci-003 | few-shot, 7 demos · Report-Extraction validation | REP F1: 50.45 -> 30.55 | Hurt |
| fine-tuned model vs gpt-4 for drugs and reactions | FLAN-T5-Large · attribute-level validation | F1: reactions 12.62 -> 34.13; drugs 50.99 -> 61.83 | Improved |
| fine-tuned model vs gpt-4 for seriousness and patientsex | FLAN-T5-Large · attribute-level validation | F1: seriousness 94.00 vs 92.90; patientsex 93.00 vs 92.65 | No clear effect |
Closest papers by meaning
- PHEE: A Dataset for Pharmacovigilance Event Extraction from Text (EMNLP 2022 · similarity 0.91)
- Entity Only vs. Inline Approaches: Evaluating LLMs for Adverse Drug Event Detection in Clinical Text (Student Abstract) (AAAI 2025 · similarity 0.87)
- SafeDrug: A Benchmark Dataset for Safety-Critical Pharmacological Reasoning in LLMs (NeurIPS 2026 · similarity 0.86)
- ExDDI: Explaining Drug-Drug Interaction Predictions with Natural Language (AAAI 2025 · similarity 0.82)
- MedSafetyBench: Evaluating and Improving the Medical Safety of Large Language Models (NeurIPS 2024 · similarity 0.82)
- UniTox: Leveraging LLMs to Curate a Unified Dataset of Drug-Induced Toxicity from FDA Labels (NeurIPS 2024 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
