AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

Co$^2$PT: Mitigating Bias in Pre-trained Language Models through Counterfactual Contrastive Prompt Tuning

Xiangjue Dong, Ziwei Zhu, Zhuoer Wang, Maria Teleki, James Caverlee

EMNLP 2023Vision-language and multimodal › CLIP and zero-shotapproach: Parameter-efficient visual tuning

George Mason University

Read the paperPlace an idea next to itCheck your own paper ↗

15measured effects
7improved
1no clear effect
7hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

This paper tried a common change: Add a contrastive loss

add counterfactual-pair contrastive loss to PT+CDA · Bias-STS-B · average absolute difference (lower better): 0.291 -> 0.058 Improved

What 1,541 accepted papers report for this change

See this change in detailMatched by the wording of each paper's own result, read by AI from the full text. Papers report gains more often than failures, so this shows what gets published, not the chance a change works.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add counterfactual contrastive prompt tuning (Co2PT) to PTPT (BERT-base) · Bias-STS-Baverage absolute difference (lower better): 0.321 -> 0.058Improved
add Co2PT to PTPT (BERT-base) · Bias-NLINet Neutral: 0.741 -> 0.877Improved
add Co2PT to PTPT (BERT-base) · Bias-in-BiosGAP TPR (lower better): 3.171 -> 2.537Improved
add Co2PT to PTPT (BERT-base) · Bias-NLIaccuracy: 0.898 -> 0.886Hurt
prompt-tune (PT) instead of fine-tune BERTBERT · Bias-STS-Baverage absolute difference (lower better): 0.282 -> 0.321Hurt
add Co2PT to Context-DebiasContext-Debias · Bias-STS-Baverage absolute difference (lower better): 0.332 -> 0.088Improved
add Co2PT to Auto-DebiasAuto-Debias · Bias-STS-Baverage absolute difference (lower better): 0.312 -> 0.068Improved
add Co2PT to MABELMABEL · Bias-STS-Baverage absolute difference (lower better): 0.066 -> 0.068No clear effect
add counterfactual data augmentation to PT without contrastive loss (ablation)PT · Bias-STS-Baverage absolute difference (lower better): 0.321 -> 0.291Improved
add counterfactual-pair contrastive loss to PT+CDA (ablation)PT+CDA · Bias-STS-Baverage absolute difference (lower better): 0.291 -> 0.058Improved
add contrastive loss on non-augmented inputs to Co2PT (ablation)Co2PT · Bias-STS-Baverage absolute difference (lower better): 0.058 -> 0.117Hurt
use task-agnostic NLI counterfactual pairs instead of task-specific pairs (ablation)Co2PT · Bias-STS-Baverage absolute difference (lower better): 0.058 -> 0.080Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy