AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

Black-Box Tuning of Vision-Language Models with Effective Gradient Approximation

Zixian Guo, Yuxiang Wei, Ming Liu, Zhilong Ji, Jinfeng Bai, Yiwen Guo, Wangmeng Zuo

EMNLP 2023 · Vision-language and multimodal › CLIP and zero-shot · approach: Parameter-efficient visual tuning · 16 citations (OpenAlex) · Harbin Institute of Technology, Pazhou Lab

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add Tip-Adapter visual adapter (ablation)CBBT prompt tuning (RN50) · 11 datasets avg, 16-shotaccuracy: 69.3 -> 76.1Improved
add CLIP-Adapter visual adapter (ablation)CBBT prompt tuning (ViT/B16) · 11 datasets avg, 16-shotaccuracy: 75.5 -> 81.0Improved
black-box textual prompt tuning instead of zero-shot hard promptCBBT w/o adapter (ViT/B16) · 11 datasets avg, 16-shotaccuracy: 65.2 -> 75.5Improved
use textual prompt tuning with gradient approximation instead of BlackVIPCBBT w/o adapter (ViT/B16) · 11 datasets avgaccuracy: 68.2 -> 75.5Improved
use black-box prompt tuning instead of white-box CoOp (1 ctx)CBBT w/o adapter (RN50) · 11 datasets avgaccuracy: 70.6 -> 69.3Hurt
use perturbation-based gradient approximation instead of SPSA-GC (ablation)CBBT w/o adapter (RN50) · EuroSATaccuracy: 60.1 -> 62.6Improved
use perturbation-based gradient approximation instead of CMA-ES (ablation)CBBT w/o adapter (RN50) · EuroSATaccuracy: 61.9 -> 62.6Improved
alternate prompt and adapter updates instead of prompt then adapter (ablation)Ours (CLIP-Adapter) · EuroSATaccuracy: 84.0 -> 85.1Improved
alternate prompt and adapter updates instead of adapter then prompt (ablation)Ours (CLIP-Adapter) · EuroSATaccuracy: 82.7 -> 85.1Improved
lengthen prompt with fixed q=256 (ablation)CBBT w/o adapter · EuroSATaccuracy: 77.3 (M=1) -> 70.0 (M=4)Hurt
scale q proportionally with prompt length (ctx 4, q=1024) (ablation)CBBT w/o adapter · EuroSATaccuracy: 70.0 -> 79.6Improved
use LAMB instead of Adam optimizer (ablation)CBBT prompt optimization · 11 datasetsaccuracyNo clear effect

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy