Research map / Vision-language and multimodal / Human and embodied modeling
Normal-Abnormal Decoupling Memory for Medical Report Generation
Guosheng Zhao, Yan Yan, Zijian Zhao
Shandong University · Illinois Institute of Technology
Read the paperPlace an idea next to itCheck your own paper ↗
10measured effects
7improved
1no clear effect
1hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MIMIC-CXR leaderboard BLEU-4 0.13 · rank 14 of 36 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add BioViL initialization of the ResNet visual extractor (ablation) | NADM · MIMIC-CXR test | BLEU-4: 0.121 -> 0.130 | Improved |
| add decoupled normal/abnormal semantic extractor (SE) (ablation) | NADM · MIMIC-CXR test | BLEU-4: 0.120 -> 0.130 | Improved |
| add abnormal pattern memory encoder (APE-MHA) (ablation) | NADM · MIMIC-CXR test | BLEU-4: 0.119 -> 0.130 | Improved |
| add APE-MHA (ablation) | NADM · MIMIC-CXR test | METEOR: 0.161 -> 0.155 | Hurt |
| add learned report loss weighting (WE) (ablation) | NADM · MIMIC-CXR test | BLEU-4: 0.124 -> 0.130 | Improved |
| add learned report loss weighting (WE) (ablation) | NADM · MIMIC-CXR test | ROUGE-L: 0.289 -> 0.289 | No clear effect |
| increase abnormal memory capacity (multiple of 49) (ablation) | NADM · MIMIC-CXR test | BLEU-4: rises with capacity then degrades beyond a threshold | Mixed |
| use proposed model instead of R2GenRL baseline | NADM vs R2GenRL · MIMIC-CXR test | F1 (CE): 0.292 -> 0.415 | Improved |
| use proposed model instead of MSAT | NADM vs MSAT · MIMIC-CXR test | BLEU-4: 0.120 -> 0.130 | Improved |
| add abnormal semantics and normal semantics to SE (setting c vs b) (ablation) | NADM · MIMIC-CXR test | BLEU-4: 0.120 -> 0.130 | Improved |
Closest papers by meaning
- Learning Visual-Semantic Embeddings for Reporting Abnormal Findings on Chest X-rays (EMNLP 2020 · similarity 0.91)
- Visual-Textual Attentive Semantic Consistency for Medical Report Generation (ICCV 2021 · similarity 0.88)
- Knowledge-Driven Encode, Retrieve, Paraphrase for Medical Image Report Generation (AAAI 2019 · similarity 0.87)
- Reformulating Radiology Report Error Detection as Sentence-Level Vision-Language Learning (EMNLP 2026 · similarity 0.87)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.86)
- AHIVE: Anatomy-aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval (CVPR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.