Research map / Vision-language and multimodal / CLIP and zero-shot
Reformulating Radiology Report Error Detection as Sentence-Level Vision-Language Learning
Dabin Min, Kyungmin Jeon, Dongheon Lee, Chang Min Park
Seoul National University Graduate School · Seoul National University · Seoul National University Hospital · Seoul National University College of Medicine · Seoul National University Medical Research Center
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| sentence-level instead of exam-level supervision (SenRED vs Exam-1SentErr) | error detector · MIMIC-CXR test | macro-F1: 0.610 -> 0.796 | Improved |
| sentence-level instead of exam-level supervision | error detector · Open-i test | macro-F1: 0.538 -> 0.743 | Improved |
| sentence-level supervision for mislocalization | error detector · MIMIC-CXR test | MISLOC F1: 0.327 -> 0.695 | Improved |
| sentence-level supervision for mislocalization | error detector · Open-i test | MISLOC F1: 0.255 -> 0.593 | Improved |
| SenRED vs zero-shot VLMs (best: Qwen3-VL-4B) | SenRED · MIMIC-CXR confirmed (sentence-level) | macro-F1: 0.411 -> 0.833 | Improved |
| SenRED vs MedGemma-4B (same MedSigLIP encoder) | SenRED · Open-i confirmed (sentence-level) | macro-F1: 0.121 -> 0.802 | Improved |
| evaluate on radiologist-confirmed subset | SenRED · MIMIC-CXR (sentence-level) | macro-F1: 0.796 -> 0.833 | Improved |
| evaluate on radiologist-confirmed subset | SenRED · Open-i (sentence-level) | macro-F1: 0.743 -> 0.802 | Improved |
| sentence-wise verification then strict aggregation vs Exam-1SentErr | SenRED · MIMIC-CXR confirmed (exam-level) | macro-F1: 0.568 -> 0.658 | Improved |
| sentence-wise verification then strict aggregation vs Exam-1SentErr | SenRED · Open-i confirmed (exam-level) | macro-F1: 0.453 -> 0.659 | Improved |
| use single-target top-1 aggregation | SenRED · MIMIC-CXR confirmed (exam-level) | macro-F1: 0.658 -> 0.712 | Improved |
| use sentence-conditioned cross-attention/Perceiver head instead of pooled MLP head (ablation) | SenRED · MIMIC-CXR test | MISLOC F1: 0.630 -> 0.695 | Improved |
Closest papers by meaning
- Unify, Align and Refine: Multi-Level Semantic Alignment for Radiology Report Generation (ICCV 2023 · similarity 0.90)
- CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation (NeurIPS 2025 · similarity 0.89)
- CURE: Curriculum-guided Multi-task Training for Reliable Anatomy Grounded Report Generation (CVPR 2026 · similarity 0.89)
- CXReasonBench: A Benchmark for Evaluating Structured Diagnostic Reasoning in Chest X-rays (NeurIPS 2025 · similarity 0.89)
- RadZero: Similarity-Based Cross-Attention for Explainable Vision-Language Alignment in Chest X-ray with Zero-Shot Multi-Task Capability (NeurIPS 2025 · similarity 0.88)
- Bootstrapping Chest CT Image Understanding by Distilling Knowledge from X-ray Expert Models (CVPR 2024 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
