AI Paper Atlas

Research map / Large language models / Instruction and fine-tuning

MedCare: Advancing Medical LLMs through Decoupling Clinical Alignment and Knowledge Aggregation

Yusheng Liao, Shuyang Jiang, Zhe Chen, Yanfeng Wang, Yu Wang

EMNLP 2024Large language models › Instruction and fine-tuningapproach: Calibration and knowledge in LLM tuning10 citations (OpenAlex)

Shanghai Jiao Tong University · Fudan University · Shanghai AI Laboratory

Read the paperPlace an idea next to it

12measured effects
8improved
1no clear effect
3hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
drop Noise Aggregator after the first stage (ablation)MedCare-1.8B MKA · knowledge-intensive Avg.accuracy: 41.16 -> 46.95Improved
drop Noise Aggregator after the first stage (ablation)MedCare-1.8B MKA · CBLUECBLUE score: 57.09 -> 8.15Hurt
add the second-stage downstream alignment with orthogonal loss (ablation)MedCare-1.8B · CBLUECBLUE score: 8.15 -> 62.05Improved
add the second-stage downstream alignment with orthogonal loss (ablation)MedCare-1.8B · knowledge-intensive Avg.accuracy: 46.95 -> 43.20Hurt
add orthogonal loss in the alignment stage (ablation)MedCare-1.8B · knowledge-intensive Avg.accuracy: 41.95 -> 43.20Improved
add orthogonal loss in the alignment stage (ablation)MedCare-1.8B · CBLUECBLUE score: 55.89 -> 62.05Improved
use asymmetric KA/NA instead of two parallel LoRAs (ablation)MedCare-1.8B · CBLUECBLUE score: 55.05 -> 57.09Improved
remove one FFN LoRA module from parallel LoRA (ablation)Parallel LoRA · knowledge-intensive Avg.accuracy: 40.43 -> 43.07 (w/o LoRA 1)Improved
compare MedCare-7B with other PEFT methodsQwen1.5-7B · knowledge-intensive Avg.accuracy: DoRA 59.18 vs MedCare 60.29Improved
fine-tune on Chinese data only, test on English medical setsMedCare vs other PEFT · English medical Avg.accuracy: 49.07 -> 50.07Improved
increase the second-stage alignment data (ablation)MedCare · knowledge capacityaccuracyNo clear effect
use less first-stage data with vanilla MoLoRA (ablation)MoLoRA · knowledge examsaccuracyHurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.