Research map / Large language models / Instruction and fine-tuning
MedCare: Advancing Medical LLMs through Decoupling Clinical Alignment and Knowledge Aggregation
Yusheng Liao, Shuyang Jiang, Zhe Chen, Yanfeng Wang, Yu Wang
Shanghai Jiao Tong University · Fudan University · Shanghai AI Laboratory
Read the paperPlace an idea next to it
12measured effects
8improved
1no clear effect
3hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| drop Noise Aggregator after the first stage (ablation) | MedCare-1.8B MKA · knowledge-intensive Avg. | accuracy: 41.16 -> 46.95 | Improved |
| drop Noise Aggregator after the first stage (ablation) | MedCare-1.8B MKA · CBLUE | CBLUE score: 57.09 -> 8.15 | Hurt |
| add the second-stage downstream alignment with orthogonal loss (ablation) | MedCare-1.8B · CBLUE | CBLUE score: 8.15 -> 62.05 | Improved |
| add the second-stage downstream alignment with orthogonal loss (ablation) | MedCare-1.8B · knowledge-intensive Avg. | accuracy: 46.95 -> 43.20 | Hurt |
| add orthogonal loss in the alignment stage (ablation) | MedCare-1.8B · knowledge-intensive Avg. | accuracy: 41.95 -> 43.20 | Improved |
| add orthogonal loss in the alignment stage (ablation) | MedCare-1.8B · CBLUE | CBLUE score: 55.89 -> 62.05 | Improved |
| use asymmetric KA/NA instead of two parallel LoRAs (ablation) | MedCare-1.8B · CBLUE | CBLUE score: 55.05 -> 57.09 | Improved |
| remove one FFN LoRA module from parallel LoRA (ablation) | Parallel LoRA · knowledge-intensive Avg. | accuracy: 40.43 -> 43.07 (w/o LoRA 1) | Improved |
| compare MedCare-7B with other PEFT methods | Qwen1.5-7B · knowledge-intensive Avg. | accuracy: DoRA 59.18 vs MedCare 60.29 | Improved |
| fine-tune on Chinese data only, test on English medical sets | MedCare vs other PEFT · English medical Avg. | accuracy: 49.07 -> 50.07 | Improved |
| increase the second-stage alignment data (ablation) | MedCare · knowledge capacity | accuracy | No clear effect |
| use less first-stage data with vanilla MoLoRA (ablation) | MoLoRA · knowledge exams | accuracy | Hurt |
Closest papers by meaning
- MedJourney: Benchmark and Evaluation of Large Language Models over Patient Clinical Journey (NeurIPS 2024 · similarity 0.90)
- Medmarks: A Comprehensive Open-Source LLM Benchmark Suite for Medical Tasks (NeurIPS 2026 · similarity 0.90)
- Hierarchical Divide-and-Conquer for Fine-Grained Alignment in LLM-Based Medical Evaluation (AAAI 2025 · similarity 0.88)
- MedAlign: A Clinician-Generated Dataset for Instruction Following with Electronic Medical Records (AAAI 2024 · similarity 0.88)
- MedCalc-Bench: Evaluating Large Language Models for Medical Calculations (NeurIPS 2024 · similarity 0.88)
- Efficiently Democratizing Medical LLMs for 50 Languages via a Mixture of Language Family Experts (ICLR 2025 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
