AI Paper Atlas

Research map / Large language models / AI and society

GREEN: Generative Radiology Report Evaluation and Error Notation

Sophie Ostmeier, Justin Xu, Zhihong Chen, Maya Varma, Louis Blankemeier, Christian Bluethgen, Arne Edward Michalson, Michael Moseley, Curtis Langlotz, Akshay S Chaudhari, Jean-Benoit Delbrouck

EMNLP 2024Large language models › AI and societyapproach: AI for health and public decisions273 citations (OpenAlex)

Read the paperPlace an idea next to itCheck your own paper ↗

9measured effects
8improved
1no clear effect

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
pretrain the evaluator on radiology text (RadLLaMA-2 vs LLaMA-2) (ablation)GREEN model (LLaMA-2 7B) · ReXVal external validationMAE of significant error count: 2.62 -> 1.54Improved
pretrain on radiology text (RadPhi-2 vs Phi-2) (ablation)GREEN model (Phi-2 2.7B) · ReXVal external validationMAE of significant error count: 2.10 -> 2.08No clear effect
pretrain on radiology text (RadPhi-2 vs Phi-2) (ablation)GREEN model (Phi-2 2.7B) · Internal test set vs GPT-4MAE of significant error count: 0.84 -> 0.63Improved
use GREEN score instead of Kendall correlation of classical metric RadGraphmetric vs. radiologist total error count · ReXValKendall's Tau: 0.57 (F1RadGraph) -> 0.63 (GREEN)Improved
apply GREEN score formula to GPT-4 outputs instead of asking GPT-4 for preference directly (ablation)GPT-4 · Expert preferencesaccuracy: 0.23 -> 0.68Improved
use GREEN score instead of summed error count (ablation)GREEN · Expert preferencesaccuracy: 0.57 -> 0.62Improved
fine-tune on additional out-of-CXR modality data (ablation)GREEN model · MIMIC-IV-NotesMAE of significant error count: 1.05 -> 0.61Improved
fine-tune on additional out-of-CXR modality data (ablation)GREEN model · Abdominal CT, OODMAE of significant error count: 5.31 -> 3.12Improved
fine-tune on additional out-of-CXR modality data (ablation)GREEN model · Abdominal CT, OODDelta GREEN: 0.21 -> 0.17Improved

Later papers that compared with this method

2 later accepted papers report GREEN as a baseline in their results tables; 2 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy