Research map / Large language models / AI and society
GREEN: Generative Radiology Report Evaluation and Error Notation
Sophie Ostmeier, Justin Xu, Zhihong Chen, Maya Varma, Louis Blankemeier, Christian Bluethgen, Arne Edward Michalson, Michael Moseley, Curtis Langlotz, Akshay S Chaudhari, Jean-Benoit Delbrouck
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| pretrain the evaluator on radiology text (RadLLaMA-2 vs LLaMA-2) (ablation) | GREEN model (LLaMA-2 7B) · ReXVal external validation | MAE of significant error count: 2.62 -> 1.54 | Improved |
| pretrain on radiology text (RadPhi-2 vs Phi-2) (ablation) | GREEN model (Phi-2 2.7B) · ReXVal external validation | MAE of significant error count: 2.10 -> 2.08 | No clear effect |
| pretrain on radiology text (RadPhi-2 vs Phi-2) (ablation) | GREEN model (Phi-2 2.7B) · Internal test set vs GPT-4 | MAE of significant error count: 0.84 -> 0.63 | Improved |
| use GREEN score instead of Kendall correlation of classical metric RadGraph | metric vs. radiologist total error count · ReXVal | Kendall's Tau: 0.57 (F1RadGraph) -> 0.63 (GREEN) | Improved |
| apply GREEN score formula to GPT-4 outputs instead of asking GPT-4 for preference directly (ablation) | GPT-4 · Expert preferences | accuracy: 0.23 -> 0.68 | Improved |
| use GREEN score instead of summed error count (ablation) | GREEN · Expert preferences | accuracy: 0.57 -> 0.62 | Improved |
| fine-tune on additional out-of-CXR modality data (ablation) | GREEN model · MIMIC-IV-Notes | MAE of significant error count: 1.05 -> 0.61 | Improved |
| fine-tune on additional out-of-CXR modality data (ablation) | GREEN model · Abdominal CT, OOD | MAE of significant error count: 5.31 -> 3.12 | Improved |
| fine-tune on additional out-of-CXR modality data (ablation) | GREEN model · Abdominal CT, OOD | Delta GREEN: 0.21 -> 0.17 | Improved |
Later papers that compared with this method
2 later accepted papers report GREEN as a baseline in their results tables; 2 of them report a better number on most of the results they share with it.
- CREPE: Rapid Chest X-ray Report Evaluation by Predicting Multi-category Error Counts (EMNLP 2025 · better on 5 of 7 shared results)
- HARE: an entity and relation centric evaluation framework for histopathology reports (EMNLP 2025 · better on 5 of 5 shared results)
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.89)
- Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation (NeurIPS 2026 · similarity 0.88)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.88)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.88)
- GEMA-Score: Granular Explainable Multi-Agent Scoring Framework for Radiology Report Evaluation (AAAI 2026 · similarity 0.87)
- CURE: Curriculum-guided Multi-task Training for Reliable Anatomy Grounded Report Generation (CVPR 2026 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
