Research map / Large language models / Language, safety and interpretability
RaTEScore: A Metric for Radiology Report Generation
Weike Zhao, Chaoyi Wu, Xiaoman Zhang, Ya Zhang, Yanfeng Wang, Weidi Xie
Shanghai Jiao Tong University
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use RaTEScore instead of the best baseline (RadGraph F1) | RaTEScore · ReXVal | Kendall tau: 0.515 -> 0.527 | Improved |
| use RaTEScore instead of the best baseline (RadGraph) | RaTEScore · RaTE-Eval paragraph-level | Pearson: 0.624 -> 0.653 | Improved |
| use RaTEScore instead of CheXbert on synthetic reports | RaTEScore · RaTE-Eval synthetic reports | accuracy: 0.666 -> 0.670 | Improved |
| use RaTEScore instead of overlap-based BLEU | RaTEScore · RaTE-Eval paragraph-level | Pearson: 0.409 -> 0.653 | Improved |
| encode entities with BioLORD-2023-C instead of MedCPT (ablation) | RaTEScore · RaTE-Eval sentence-level | Pearson: 0.498 -> 0.540 | Improved |
| encode entities with BioLORD-2023-C instead of CXR-BERT (ablation) | RaTEScore · RaTE-Eval sentence-level | Pearson: 0.368 -> 0.540 | Improved |
| train NER on Radiopaedia plus MIMIC-IV instead of Radiopaedia only (ablation) | IOB NER (DeBERTa_v3) · RaTE-NER test | F1: 0.541 -> 0.571 | Improved |
| train NER on Radiopaedia plus MIMIC-IV instead of MIMIC-IV only (ablation) | IOB NER (DeBERTa_v3) · RaTE-NER test | F1: 0.531 -> 0.571 | Improved |
| pretrain on other NER data (Medical-NER) instead of DeBERTa_v3 init (ablation) | IOB NER · RaTE-NER test | F1: 0.571 -> 0.565 | No clear effect |
| use Span-based instead of IOB-based NER training (ablation) | NER module · RaTE-NER test | recall / precision: recall 0.575 -> 0.676 (BiomedBERT); F1 0.571 -> 0.610 | Mixed |
| vary BERT initialization within Span-based NER (ablation) | Span-based NER · RaTE-NER test | F1: 0.601 - 0.610 (excluding MedCPT-Q-Enc. 0.556) | No clear effect |
Later papers that compared with this method
1 later accepted paper reports RaTEScore as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.
- HARE: an entity and relation centric evaluation framework for histopathology reports (EMNLP 2025 · better on 1 of 1 shared result)
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards (EMNLP 2022 · similarity 0.90)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.89)
- GEMA-Score: Granular Explainable Multi-Agent Scoring Framework for Radiology Report Evaluation (AAAI 2026 · similarity 0.87)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.86)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.86)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
