AI Paper Atlas

Research map / Multi-agent systems and games / LLM agents

MEDitor: A Plug-and-Play Medical Multi-Agent Routing Protocol

Yunwei Wang, Xianrui Zhang, Qiankun Ma, Rongjie Wang, Zhen Song, Haofei Wang

EMNLP 2026Multi-agent systems and games › LLM agentsapproach: Agent data synthesis and behavior studies0 citations (OpenAlex)

Peng Cheng Laboratory · Southern University of Science and Technology

Read the paperPlace an idea next to itCheck your own paper ↗

11measured effects
8improved
2no clear effect
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

On benchmark leaderboards

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add disagreement-triggered Deep Path (EGC, debate, judge) to Shallow-only (ablation)MEDitor · Avg5accuracy (%): 61.40 -> 65.94 (+4.54, p < 0.001)Improved
use MEDitor with ~7B experts instead of Llama-3.1-70B-InstructMEDitor · Avg5accuracy (%): 65.57 -> 65.94 (+0.37, CI [-0.44, 1.18], p = 0.37)No clear effect
add Constrained Judge (Debate only -> full stack) (ablation)MEDitor · Avg5accuracy (%): 63.62 -> 65.94Improved
add EGC evidence grounding (Debate+Judge -> full) (ablation)MEDitor · Avg5accuracy (%): 64.61 -> 65.94Improved
add Debate (EGC+Judge -> full) (ablation)MEDitor · Avg5accuracy (%): 64.38 -> 65.94Improved
add Judge (EGC+Debate -> full) (ablation)MEDitor · Avg5accuracy (%): 64.40 -> 65.94Improved
replace default experts with Qwen3-8B and Meerkat-8B (ablation)MEDitor · Avg5accuracy (%): Shallow-only 59.75 -> MEDitor 64.04Improved
vary fallback coefficient alpha over 0 to 1.0 (ablation)MEDitor fallback · Avg5overall accuracy (%): 65.83-65.94 (0.11 range)No clear effect
route only disagreement cases to Deep Path instead of all instances (ablation)MEDitor · five-benchmark suitemean latency (s): 55.81 -> 22.65 s; 59.4% latency reductionImproved
use MEDitor routed Deep Path on disagreement casesMEDitor · 2,398 disagreement casesprediction changes: 672 incorrect->correct vs 293 correct->incorrect; net +379Mixed
apply MEDitor to real hospital arrhythmia casesMEDitor · 312 hospital casesaccuracy (%): 57.0 -> 78.0Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy