Research map / Large language models / Reasoning and chain of thought
Agentic Reward Modeling for Medical Reasoning
Hang Zhang, Ruheng Wang, Yuelyu Ji, Mingu Kwak, Xizhi Wu, Chenyu Li, Li Zhang, Wenqi Shi, Yifan Peng, Yanshan Wang
University of Pittsburgh · UT Southwestern Medical Center · Washington University in Saint Louis · Weill Cornell Medicine
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MedQA leaderboard accuracy 77.14 · rank 24 of 71 papers
- MedMCQA leaderboard accuracy 64.7 · rank 13 of 30 papers
- MMLU-Med leaderboard accuracy 85.58 · rank 3 of 11 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add tool access (search) to RL-trained verifier (ablation) | Med-TIV on Qwen2.5-7B · MedQA | accuracy: 69.60 -> 70.54 | Improved |
| add tool access (search) to RL-trained verifier (ablation) | Med-TIV on AlphaMed-7B · MedQA | accuracy: 76.12 -> 77.14 | Improved |
| add RL training of the verifier (ablation) | Qwen2.5-7B generator · MedQA | accuracy: 60.96 -> 69.60 | Improved |
| mask retrieved evidence in verifier input (ablation) | Med-TIV · MedQA verification | accuracy: 72.2% -> 47.1% | Hurt |
| use Hard Weighted SC instead of Best-of-N (ablation) | Med-TIV on Qwen2.5-7B · MedQA | accuracy: 72.35 -> 75.26 | Improved |
| use verifier-filtered voting instead of plain self-consistency | Qwen2.5-7B · MedQA | accuracy: 66.38 -> 75.26 | Improved |
| use Med-TIV verifier on larger generator | Qwen2.5-32B · MedQA | accuracy: 73.21 -> 75.96 | Improved |
| Hard vs Soft weighted SC on Qwen2.5-32B (ablation) | Med-TIV on Qwen2.5-32B · MedQA | accuracy: 75.96 vs 75.96 | No clear effect |
| second RL iteration after the first (ablation) | Med-TIV on Llama3.1-8B · MedQA | accuracy: 75.26 -> 75.86 | No clear effect |
| replace Qwen2.5-7B backbone with Llama3.1-8B for the verifier (ablation) | Med-TIV · MedQA | accuracy: 72.35 -> 75.86 | Improved |
| use Med-TIV verifier vs Med-PRM for test-time search | Qwen2.5-7B generator · MedQA sampling efficiency | accuracy at sampling budget: 72.1% at N=4 vs 70.0% at N=32 (Med-PRM) | Improved |
| use Med-PRM verifier instead of self-consistency (no verifier) | Qwen2.5-7B generator · AgentClinic-MedQA | accuracy: 63.55 -> 61.21 | Hurt |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- MedS3 — MedS³: Towards Medical Slow Thinking with Self-Evolved Soft Dual-sided Process Supervision (AAAI 2026) · better on 6 of 6 shared results
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- MedS³: Towards Medical Slow Thinking with Self-Evolved Soft Dual-sided Process Supervision (AAAI 2026 · similarity 0.89)
- MMedAgent-RL: Optimizing Multi-Agent Collaboration for Multimodal Medical Reasoning (ICLR 2026 · similarity 0.88)
- MedVR: Annotation-Free Medical Visual Reasoning via Agentic Reinforcement Learning (ICLR 2026 · similarity 0.87)
- MedAgent-Pro: Towards Evidence-based Multi-modal Medical Diagnosis via Reasoning Agentic Workflow (ICLR 2026 · similarity 0.87)
- Simulating Viva Voce Examinations to Evaluate Clinical Reasoning in Large Language Models (NeurIPS 2025 · similarity 0.87)
- CARE: Towards Clinical Accountability in Multi-Modal Medical Reasoning with an Evidence-Grounded Agentic Framework (ICLR 2026 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
