Research map / Vision-language and multimodal / Multimodal LLMs
Auditing and Mitigating Paraphrase Fragility in Medical Vision-Language Models
Syed Faizan, Anuradha Chandramohan, Parameswari Krishnamurthy
International Institute of Information Technology (IIIT) Hyderabad · Christian Medical College
Read the paperPlace an idea next to itCheck your own paper ↗
13measured effects
6improved
2no clear effect
4hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add locked category-conditioned LoRA | eight VLM checkpoints · VQA-RAD Cat 7 | clinical flip rate: relative reduction 59.0% to 75.8% | Improved |
| add locked Cat 7 LoRA | MedGemma-27B · VQA-RAD | paraphrase accuracy: 68.4 -> 75.5 | Improved |
| add locked Cat 7 LoRA | MedGemma-27B · VQA-RAD | base accuracy: 79.6 -> 73.9 | Hurt |
| add locked Cat 7 LoRA | MedGemma-4B · VQA-RAD Cat 7 | paraphrase accuracy: 55.1 -> 75.9 | Improved |
| add locked Cat 7 LoRA | MedGemma-4B · VQA-RAD Cat 7 | ECE: 0.403 -> 0.208 | Improved |
| replace category-conditioned LoRA with pooled LoRA (ablation) | MedGemma-4B · VQA-RAD Cat 7 | relative flip reduction: 73.9 -> 71.08 | No clear effect |
| clamp SAE features to zero at layer 17 (ablation) | MedGemma-4B · VQA-RAD Cat 7 | flip rate: 47.99 -> 45.21 (5.8% relative) | No clear effect |
| broaden LoRA layer window from 15-19 to 12-21 (ablation) | MedGemma-4B LoRA recipe · VQA-RAD Cat 7 | relative flip reduction: +10 pp | Improved |
| add MLP targets to attention-only LoRA (ablation) | MedGemma-4B LoRA recipe · VQA-RAD Cat 7 | relative flip reduction: +14 pp | Improved |
| add heterogeneous rank and self-curriculum (v5) (ablation) | MedGemma-4B LoRA recipe · VQA-RAD Cat 7 | relative flip reduction: -4.8 pp | Hurt |
| place LoRA on later layers 25-29 instead of 10-14 (ablation) | MedGemma-4B · VQA-RAD Cat 7 | relative flip reduction: 74.99 -> 21.90 | Hurt |
| apply LLM-judge equivalence filter (ablation) | Cat 7 LoRA evaluation · VQA-RAD calibration Cat 7 | relative flip reduction: 87.07 (judge) vs 79.48 (clinician gold) vs 80.14 (no filter) | Mixed |
Closest papers by meaning
- MedVIGIL: Evaluating Trustworthy Medical VLMs Under Broken Visual Evidence (NeurIPS 2026 · similarity 0.89)
- TIA-VL: Diagnosing and Correcting Template-Induced Ambiguity in Medical Vision-Language Decisions (EMNLP 2026 · similarity 0.88)
- OpenMedReason: Scientific Reasoning Supervision for Medical Vision–Language Models (NeurIPS 2026 · similarity 0.87)
- How Do Medical MLLMs Fail? A Study on Visual Grounding in Medical Images (ICLR 2026 · similarity 0.87)
- MediConfusion: Can you trust your AI radiologist? Probing the reliability of multimodal medical foundation models (ICLR 2025 · similarity 0.87)
- OmniMedVQA: A New Large-Scale Comprehensive Evaluation Benchmark for Medical LVLM (CVPR 2024 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.