AI Paper Atlas

Research map / Large language models / Agents, code and math

ProActIS: Boosting LLMs' Proactive Information Seeking in Dynamic Clinical Workflows with a Lightweight Exam Proposer

Ruiyang Zhang, Yushi Feng, Liang Peng, Lequan Yu

EMNLP 2026Large language models › Agents, code and mathapproach: Agent instruction-following benchmarks1 citations (OpenAlex)

The University of Hong Kong

Read the paperPlace an idea next to itCheck your own paper ↗

15measured effects
10improved
2no clear effect
2hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace single state vector with four structured channels (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.3092 -> 0.5019Improved
add hard-negative mining (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.5019 -> 0.5427Improved
add STOP-aware training (ablation)ProActIS · MIMIC-IV full-bank rankingSTOP@1: 0.7440 -> 0.9093Improved
add STOP-aware training (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.5427 -> 0.5441No clear effect
add channel calibration (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.5441 -> 0.5907Improved
add future-aware training (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.5907 -> 0.6028Improved
add VOI-inspired channel (ablation)ProActIS · MIMIC-IV full-bank rankingRecall@1: 0.4957 -> 0.6028Improved
add ProActIS Top-1/Top-3 guidance to LLM agentsDeepSeek V4 Pro, Qwen3.5-27B, Claude Sonnet 5 · MIMIC-IV dynamic workflowdiagnosis accuracy: Claude 19.9% -> 65.3% (Top-1)Improved
add ProActIS Top-1/Top-3 guidance to LLM agentsLLM agents · MIMIC-IV dynamic workflowMicro Hit: Qwen 29.37% -> 85.79% (Top-3)Improved
use Top-3 instead of Top-1 suggestions (ablation)ProActIS with LLM agents · MIMIC-IV dynamic workflowMicro Hit: Claude 61.54% -> 74.40%; diag. acc. 65.30% -> 64.80%Mixed
mask sentences not admission-available (sensitivity test) (ablation)ProActIS Top-3 + LLM · 100 test casesMicro Hit / diag. accuracy: 66.85% -> 61.25%; 57.00% -> 54.79%Hurt
adaptive-K instead of fixed Top-3 (ablation)ProActIS · MIMIC-IV testE/F coverage / diagnostic accuracy: 93.70% -> 93.78%; 3.00 -> 2.30 candidatesNo clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy