AI Paper Atlas

Research map / Federated learning and privacy / Personalized and heterogeneous FL

FedCoT: Communication-Efficient Federated Reasoning Enhancement for Large Language Models

Chuan Li, Qianyi Zhao, Fengran Mo, Cen Chen

EMNLP 2026Federated learning and privacy › Personalized and heterogeneous FLapproach: Federated prompt and LoRA tuning

East China Normal University · University of Montreal

Read the paperPlace an idea next to itCheck your own paper ↗

12measured effects
7improved
2no clear effect
3hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

On benchmark leaderboards

Measured effects reported in the paper

What was changedWhereMeasuredEffect
apply FedCoT to LLaMA-3-8B-InstructLLaMA-3-8B-Instruct · five medical QA, averageaccuracy (%): 28.56 -> 55.50Improved
apply FedCoT to Qwen2.5-7B-InstructQwen2.5-7B-Instruct · five medical QA, averageaccuracy (%): 47.14 -> 68.70Improved
self-consistency vs plain CoTLLaMA-3-8B-Instruct · five medical QA, averageaccuracy (%): 28.56 -> 28.08No clear effect
FedCoT vs FedITLLaMA-3-8B-Instruct · MedMCQAaccuracy (%): 47.29 (FedIT) vs 45.20 (FedCoT)Hurt
add Candidate Selection (ablation)FedCoT · MMLU / averageaccuracy (%): 62.90 -> 68.70 (MMLU); 54.38 -> 55.50 (avg)Improved
add Soft Labeling (ablation)FedCoT · MMLU / averageaccuracy (%): 60.30 -> 68.70 (MMLU); 53.72 -> 55.50 (avg)Improved
federated training vs local-only discriminator (ablation)FedCoT · five medical QA, averageaccuracy (%): 45.26 -> 55.50Improved
use Qwen3-0.6B-Base generative backbone as discriminator (ablation)FedCoT · five medical QA, averageaccuracy (%): 55.50 -> 38.72Hurt
use open-source Skywork reward models to select tracesLLaMA-3-8B-Instruct · five medical QAaccuracy (%): all below direct CoT averageHurt
homogeneous vs heterogeneous LoRA ranks (ablation)FedCoT · five medical QA, averageaccuracy (%): 55.06 (r=16 all) -> 55.50 (r=4,32,32,16,4)Improved
extend max generation length from 512 to 1024 (ablation)FedCoT, LLaMA-3-8B-Instruct · five medical QA, averageaccuracy (%): 52.32 -> 55.36Improved
step-wise self-evaluation instead of path discriminationclient models · medical QAself-evaluated positive rate: 81.63% to 99.98% positiveNo clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy