Contrast Prior and Fluid Pyramid Integration for RGBD Salient Object Detection

CVPR 2019 · Detection and segmentation › CNN features · approach: RGB-D salient object detection · 444 citations (OpenAlex)

Check your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use CPFP instead of PCFRGBD salient object detection · SSB1000mean F-measure: 0.818 -> 0.842Helped
Use CPFP instead of PCFRGBD salient object detection · NJU2000mean F-measure: 0.840 -> 0.850Helped
Use CPFP instead of PCFRGBD salient object detection · LFSDmean F-measure: 0.761 -> 0.811Helped
Use CPFP instead of PCFRGBD salient object detection · RGBD135mean F-measure: 0.765 -> 0.815Helped
Use CPFP instead of PCFRGBD salient object detection · NLPRmean F-measure: 0.809 -> 0.840Helped
Add a contrast-enhanced net for depth information (ablation)VGG-16 RGBD detector · NJU2000mean F-measure: 0.714 -> 0.756Helped
Use the original depth map directly instead of contrast-enhancing it (ablation)VGG-16 RGBD detector · NJU2000mean F-measure: 0.714 -> 0.708Hurt
Add fluid pyramid integration to the contrast-enhanced model (ablation)VGG-16 RGBD detector · NJU2000mean F-measure: 0.756 -> 0.851Helped
Replace fluid pyramid integration with direct multi-scale fusion (ablation)VGG-16 RGBD detector with contrast enhancement · NJU2000mean F-measure: 0.851 -> 0.748Hurt
Replace fluid pyramid integration with traditional pyramid fusion (ablation)VGG-16 RGBD detector with contrast enhancement · NJU2000mean F-measure: 0.851 -> 0.789Hurt
Use original depth rather than contrast enhancement while retaining fluid pyramid integration (ablation)VGG-16 RGBD detector · NJU2000mean F-measure: 0.783 -> 0.851Hurt
Add fluid pyramid integration without the contrast-enhanced net (ablation)VGG-16 RGBD detector · NJU2000mean F-measure: 0.714 -> 0.758Helped