AI Paper Atlas

Research map / Vision-language and multimodal / Human and embodied modeling

Generating Reports or Repeating Templates? Measuring and Mitigating Template Collapse in 3D CT Report Generation

Tom Maye-Lasserre, Yitong Li, Bailiang Jian, Morteza Ghahremani, Benedikt Wiestler, Christian Wachinger

EMNLP 2026Vision-language and multimodal › Human and embodied modelingapproach: Medical vision-language models5 citations (OpenAlex)

Technical University of Munich · Munich Center for Machine Learning

Read the paperPlace an idea next to itCheck your own paper ↗

14measured effects
10improved
3no clear effect
1hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
decouple clinical detection from language synthesis (CLarGen vs best VLM baseline)3D CT report generation · CT-RATE testmacro-F1: 0.194 (HULU-Med) -> 0.486Improved
use CLarGen instead of CT-CHAT3D CT report generation · CT-RATE testCRG: 0.368 -> 0.472Improved
use CLarGen instead of baselinesreport generation · CT-RATE testROUGE-L / BLEU / METEOR: e.g. ROUGE-L 0.388 (SAMF) vs 0.298; BLEU 0.277 (CT-CHAT) vs 0.208Hurt
use CLarGen instead of baselinesreport generation · CT-RATE testrare-finding recall (Surv_rare): 0.000-0.088 -> 0.628Improved
use CLarGen instead of baselinesreport generation · CT-RATE testeffective bigram vocabulary effV2: 271-1393 -> 1826Improved
pathology-guided retrieval instead of Vol<->Vol retrieval (ablation)CLarGen · CT-RATE testmacro-F1: 0.393 -> 0.486Improved
pathology-guided retrieval instead of Vol<->Text retrieval (ablation)CLarGen · CT-RATE testmacro-F1: 0.446 -> 0.486Improved
add retrieved exemplars to predicted labels as LLM input (ablation)CLarGen · CT-RATE testmacro-F1: 0.408 (labels only) -> 0.497 (labels + exemplars)Improved
replace image-only conditioning with explicit labels+exemplars (ablation)LLM input · CT-RATE testmacro-F1: 0.294 -> 0.497Improved
use domain-specific MedGemma 27B instead of LLaMA 3.1 8B (ablation)CLarGen · CT-RATE testmacro-F1: 0.472 -> 0.486Improved
increase number of retrieved reports k from 4 to 5, then beyond (ablation)CLarGen · CT-RATE testF1: 0.483 (k=4) -> 0.489 (k=5), 0.490-0.495 for k>=6No clear effect
upgrade visual encoder from CT-CLIP to HLIP in conventional VLM (ablation)end-to-end VLM · CT-RATEmacro-F1: 0.189 -> 0.193No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update