Research map / Vision-language and multimodal / Human and embodied modeling
Generating Reports or Repeating Templates? Measuring and Mitigating Template Collapse in 3D CT Report Generation
Tom Maye-Lasserre, Yitong Li, Bailiang Jian, Morteza Ghahremani, Benedikt Wiestler, Christian Wachinger
Technical University of Munich · Munich Center for Machine Learning
Read the paperPlace an idea next to itCheck your own paper ↗
14measured effects
10improved
3no clear effect
1hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| decouple clinical detection from language synthesis (CLarGen vs best VLM baseline) | 3D CT report generation · CT-RATE test | macro-F1: 0.194 (HULU-Med) -> 0.486 | Improved |
| use CLarGen instead of CT-CHAT | 3D CT report generation · CT-RATE test | CRG: 0.368 -> 0.472 | Improved |
| use CLarGen instead of baselines | report generation · CT-RATE test | ROUGE-L / BLEU / METEOR: e.g. ROUGE-L 0.388 (SAMF) vs 0.298; BLEU 0.277 (CT-CHAT) vs 0.208 | Hurt |
| use CLarGen instead of baselines | report generation · CT-RATE test | rare-finding recall (Surv_rare): 0.000-0.088 -> 0.628 | Improved |
| use CLarGen instead of baselines | report generation · CT-RATE test | effective bigram vocabulary effV2: 271-1393 -> 1826 | Improved |
| pathology-guided retrieval instead of Vol<->Vol retrieval (ablation) | CLarGen · CT-RATE test | macro-F1: 0.393 -> 0.486 | Improved |
| pathology-guided retrieval instead of Vol<->Text retrieval (ablation) | CLarGen · CT-RATE test | macro-F1: 0.446 -> 0.486 | Improved |
| add retrieved exemplars to predicted labels as LLM input (ablation) | CLarGen · CT-RATE test | macro-F1: 0.408 (labels only) -> 0.497 (labels + exemplars) | Improved |
| replace image-only conditioning with explicit labels+exemplars (ablation) | LLM input · CT-RATE test | macro-F1: 0.294 -> 0.497 | Improved |
| use domain-specific MedGemma 27B instead of LLaMA 3.1 8B (ablation) | CLarGen · CT-RATE test | macro-F1: 0.472 -> 0.486 | Improved |
| increase number of retrieved reports k from 4 to 5, then beyond (ablation) | CLarGen · CT-RATE test | F1: 0.483 (k=4) -> 0.489 (k=5), 0.490-0.495 for k>=6 | No clear effect |
| upgrade visual encoder from CT-CLIP to HLIP in conventional VLM (ablation) | end-to-end VLM · CT-RATE | macro-F1: 0.189 -> 0.193 | No clear effect |
Closest papers by meaning
- Region-Aware Multimodal Large Language Model via SlowFast Tokenization and Pseudo-Mask Guidance for 3D CT Report Generation (ECCV 2026 · similarity 0.89)
- Better Tokens for Better 3D: Advancing Vision-Language Modeling in 3D Medical Imaging (NeurIPS 2025 · similarity 0.89)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.87)
- MEPNet: Medical Entity-Balanced Prompting Network for Brain CT Report Generation (AAAI 2025 · similarity 0.86)
- CURE: Curriculum-guided Multi-task Training for Reliable Anatomy Grounded Report Generation (CVPR 2026 · similarity 0.86)
- 3DMedAgent: Unified Perception-to-Understanding for 3D Medical Analysis (ICML 2026 · similarity 0.86)