AI Paper Atlas

Research map / Vision-language and multimodal / Multimodal LLMs

Region-Aware Multimodal Large Language Model via SlowFast Tokenization and Pseudo-Mask Guidance for 3D CT Report Generation

Sunggu Kyung, Jinyoung Seo, Hyunseok Lim, Dongyeong Kim, Hyungbin Park, Jimin Sung, Wooyoung Jo, Yoojin Nam, Namkug Kim

ECCV 2026 · Vision-language and multimodal › Multimodal LLMs · approach: Interleaved image-text generation with MLLMs · 15 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add Lesion Attribute Extractor (lesion size/location text prompts) to R+Mask (ablation)MedRegion-CT · RadGenome-Chest CT (internal, n=1551) 30% trainCRG: 0.3699 -> 0.3861Improved
add Lesion Attribute Extractor to R+Mask (ablation)MedRegion-CT · AMC zero-shotGPT-CA: 0.2323 -> 0.2564Improved
add Mask-Driven Visual Extractor to R+Attr (ablation)MedRegion-CT · RadGenome-Chest CT (internal, n=1551) 30% trainGPT-CA: 0.3807 -> 0.3839Improved
add Mask-Driven Visual Extractor to R+Attr (ablation)MedRegion-CT · AMC zero-shotGPT-CA: 0.2530 -> 0.2564Improved
add Mask + Attr to Region-based SlowFast Tokenizer (ablation)MedRegion-CT · RadGenome-Chest CT (internal, n=1551) 30% trainGREEN: 0.3930 -> 0.4025Improved
use Region-based SlowFast Tokenizer instead of conventional SlowFast (LITA) (ablation)MedRegion-CT · AMC zero-shotGPT-CA: 0.2241 -> 0.2244Improved
use Region-based SlowFast Tokenizer instead of M3D 3D ViT encoder (ablation)MedRegion-CT · RadGenome-Chest CT (internal, n=1551) 30% trainCRG: 0.3487 -> 0.3613Improved
add Mask extractor to R+Attr on ROUGE (ablation)MedRegion-CT · AMC zero-shotROUGE: 0.1628 (R+Mask) vs 0.1577 (full)Mixed
distort organ masks (ablation)MedRegion-CT · segmentation noise testBLEU: 0.3273 -> 0.2252Hurt
distort lesion masks (ablation)MedRegion-CT · segmentation noise testBLEU: 0.3273 -> 0.2986Hurt
use MedRegion-CT instead of Med3DVLMMedRegion-CT · RadGenome-Chest CT (internal, n=1551)GREEN: 0.3881 -> 0.4555Improved
use MedRegion-CT instead of RadFMMedRegion-CT · AMC (external zero-shot, n=500)BLEU: 0.1464 -> 0.1275Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy