Research map / Large language models / Language, safety and interpretability
Measuring, Localizing, and Reducing the AI-Like Writing Style of Post-Trained LLMs
Aniket Anand, Janvijay Singh, Zhewei Sun, Dilek Hakkani-Tür, Nick Feamster
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| post-train a base model (aligned vs base generations) | base LLMs · matched-prefix generations, RedPajama+ infini-gram | corpus affinity (overlap density, Coverage@10) | Hurt |
| post-train a base model | base LLMs · matched-prefix generations, Pangram | AI-detection rate: 9.2% -> 98.5% (base -> aligned) | Improved |
| post-train a base model | base LLMs · matched-prefix generations, GPTZero | AI-detection rate: 2.9% -> 84.5% (base -> aligned) | Improved |
| ablate the aligned-minus-base residual direction (PASTA) | aligned LLMs · Held-out test, Pangram | AI-detection rate: -98.0 points (Gemma-2-9B); 8 of 11 models drop by 73.2-98.0 | Improved |
| ablate the PASTA direction | OLMo-3-7B-Instruct and Tulu-3-8B-RLVR · Held-out test, Pangram | AI-detection rate: -5.8 and -6.0 points | No clear effect |
| ablate the PASTA direction | aligned LLMs · Binoculars (transfer) | AI-detection rate: decreases for 10 of 11 models; +8.5 (Tulu), +12.2 (OLMo) | Mixed |
| ablate random orthogonal directions instead of PASTA direction (ablation) | aligned LLMs · Pangram, 4 models | AI-detection rate: at most -1.6 vs -69.8 to -99.2 for PASTA | No clear effect |
| use PASTA direction instead of random direction (ablation) | aligned LLMs · 6 detectors x 4 models | AI-detection rate: larger reduction in 22 of 24 pairs | Improved |
| apply PASTA ablation to the aligned model (ablation) | aligned LLMs · LLM-judge quality | fluency and relevance vs unablated aligned: fluency +0.76, relevance +0.74 (aligned over PASTA) | Hurt |
| increase ablation strength alpha beyond 1 (ablation) | PASTA · ablation strength sweep | detection vs quality: lower detection but degraded fluency/relevance | Mixed |
| estimate PASTA direction per domain instead of domain-agnostic (ablation) | PASTA · Pangram and GPTZero, 10 model-domain cells | mean detection rate: domain-agnostic lower in 6/10, domain-specific in 3/10 | No clear effect |
| use 100 instead of 25 calibration examples (ablation) | PASTA direction · 4 models | direction cosine similarity: cosine similarity 0.92-0.96 | No clear effect |
Closest papers by meaning
- Imitate Before Detect: Aligning Machine Stylistic Preference for Machine-Revised Text Detection (AAAI 2025 · similarity 0.88)
- Few-Shot Detection of Machine-Generated Text using Style Representations (ICLR 2024 · similarity 0.86)
- Peering Through Preferences: Unraveling Feedback Acquisition for Aligning Large Language Models (ICLR 2024 · similarity 0.86)
- Exploring Intrinsic Alignments Within Text Corpus (AAAI 2025 · similarity 0.85)
- DeTeCtive: Detecting AI-generated Text via Multi-Level Contrastive Learning (NeurIPS 2024 · similarity 0.85)
- Alignment Imprint: Zero-Shot AI-Generated Text Detection via Provable Preference Discrepancy (NeurIPS 2026 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
