Research map / Large language models / Retrieval and knowledge
Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA
Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
University of Amsterdam · Amsterdam Public Health
Read the paperPlace an idea next to itCheck your own paper ↗
13measured effects
2improved
7no clear effect
3hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| rewrite textbook questions into other registers (patient, clinical note, colloquial) | textbook-trained linear probe · MedQA held-out facts | AUROC: mean -0.095; largest on clinical note | Hurt |
| test on held-out medical specialties | textbook-trained linear probe · MedQA (S-MedQA specialties) | AUROC: mean -0.031 | No clear effect |
| transfer frozen probe from MedQA to MedMCQA | textbook-trained linear probe · MedMCQA validation | AUROC: mean -0.21; MedMCQA AUROC 0.52 to 0.60 | Hurt |
| transfer frozen probe from MedQA to MMLU-medical | textbook-trained linear probe · MMLU-medical | AUROC: -0.12 | Hurt |
| reformat MedMCQA items into MedQA-style vignettes (ablation) | linear probe · MedMCQA 100 items | AUROC: 0.561 -> 0.559 | No clear effect |
| train probe on a mix of all four registers (ablation) | linear probe · non-textbook registers | AUROC: +0.061 mean; textbook cost <= 0.03 | Improved |
| replace linear probe with one-hidden-layer MLP probe (ablation) | linear probe · MedQA registers | AUROC: +0.037 mean | No clear effect |
| replace logistic probe with difference-of-means probe (ablation) | linear probe · register shift | AUROC: mean drop -.075 vs -.095; +0.070 on clinical note | No clear effect |
| apply Platt scaling to raw probe outputs (ablation) | linear probe · ECE, 16 conditions | ECE: 0.341 -> 0.135 | Improved |
| regenerate rewrites with a second generator (Gemini 3 Flash) (ablation) | benchmark · register gap | AUROC gap: 0.095 -> 0.079; same ordering | No clear effect |
| filter low-fidelity wrong-answer rewrites (ablation) | benchmark · register gap | AUROC gap: moves mean gap by at most 0.0023 | No clear effect |
| compare probe to P(True) self-evaluation baseline | linear probe · larger LLMs (Qwen2.5-7B, Llama-3-8B) | AUROC: probe +0.05 on Gemma-2-2B, +0.04 on Gemma-3-4B; tie on Llama-3-8B | No clear effect |
Closest papers by meaning
- Facts Fade Fast: Evaluating Memorization of Outdated Medical Knowledge in Large Language Models (EMNLP 2025 · similarity 0.89)
- Auditing and Mitigating Paraphrase Fragility in Medical Vision-Language Models (EMNLP 2026 · similarity 0.88)
- Trustworthy Medical Question Answering: An Evaluation-Centric Survey (EMNLP 2025 · similarity 0.88)
- When Quantization Preserves Accuracy but Not Evidence: Explanation-Aware Post-Training Quantization for Medical LLMs (EMNLP 2026 · similarity 0.87)
- MedAlign: A Clinician-Generated Dataset for Instruction Following with Electronic Medical Records (AAAI 2024 · similarity 0.87)
- MedVIGIL: Evaluating Trustworthy Medical VLMs Under Broken Visual Evidence (NeurIPS 2026 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
