AI Paper Atlas

Research map / 3D vision / Human pose estimation

Reconstructing Three-Dimensional Models of Interacting Humans

Mihai Fieraru, Mihai Zanfir, Elisabeta Oneaţă, Alin-Ionut Popa, Vlad Olaru, Cristian Sminchisescu

TPAMI 2025 · 3D vision › Human pose estimation · approach: Physics and sensor-based motion capture · 16 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add semantic 2d features as input (ablation)ISP · FlickrCI3D (75 regions)segmentation IoU: 0.300 -> 0.318Improved
add semantic 2d features as input (ablation)ISP · FlickrCI3D (17 regions)signature IoU: 0.240 -> 0.248Improved
add semantic 2d features as input (ablation)ISP · FlickrCI3D (9 regions)signature IoU: 0.410 -> 0.408No clear effect
add joint learning of contact segmentation (ablation)ISP · FlickrCI3D (17 regions)signature IoU: 0.218 -> 0.248Improved
add joint learning of contact segmentation (ablation)ISP · FlickrCI3D (75 regions)signature IoU: 0.072 -> 0.082Improved
add masking of correspondences outside estimated segmentation (ablation)ISP · FlickrCI3D (17 regions)signature IoU: 0.230 -> 0.248Improved
add masking of correspondences outside estimated segmentation (ablation)ISP · FlickrCI3D (9 regions)signature IoU: 0.385 -> 0.408Improved
coarser region granularity (75 to 9 regions) (ablation)ISP · FlickrCI3Dsignature IoU: 0.082 -> 0.408Improved
add geometric alignment term L_G on contact signatures (ablation)optimization L* · CHI3D contact frames (overall)pose error (mm): 130.7 (w/o L_G) vs Hug 180.4 -> 173.9Improved
add geometric alignment term L_G on contact signatures (ablation)optimization L* · CHI3D contact frames (overall)translation error (mm): 408.4 mm without L_G; Kick 460.1 -> 419.2Improved
add geometric alignment term L_G on contact signatures (ablation)optimization L* · CHI3D Holding handspose error (mm): 100.3 -> 100.9Hurt
add geometric alignment term L_G on contact signatures (ablation)optimization L* · CHI3D contact frames (overall)mean contact distance (mm): 420.8 -> 26.0Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 0 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy