Research map / 3D vision / Depth and stereo
Structure of Multiple Mirror System from Kaleidoscopic Projections of Single 3D Point
Kosuke Takahashi, Shohei Nobuhara
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add kaleidoscopic bundle adjustment (ablation) | Proposed calibration · Real 3-mirror calibration | reprojection error (px): 5.49 -> 3.85 | Improved |
| add bundle adjustment to Ying et al. linear solution (ablation) | Ying et al. · Real 3-mirror calibration | reprojection error (px): 317.91 -> 3.88 | Improved |
| add bundle adjustment to Takahashi et al. linear solution (ablation) | Takahashi et al. · Real 3-mirror calibration | reprojection error (px): 433.43 -> 3.88 | Improved |
| add bundle adjustment to chessboard baseline (ablation) | Baseline · Real 3-mirror calibration | reprojection error (px): 618.21 -> 3.84 | Improved |
| use proposed linear solution instead of absolute-conic linear solution | Mirror calibration · Real 3-mirror calibration | reprojection error (px): 317.91 -> 5.49 | Improved |
| after BA, proposed vs conventional methods (ablation) | Mirror calibration · Real 3-mirror calibration | reprojection error (px): 3.85 vs 3.88 | No clear effect |
| add Proposition 1 and 2 pruning together (ablation) | Chamber assignment · Synthetic 3 mirrors, noise 0 | candidates passing: 151,200 -> 796 | Improved |
| add all pruning constraints (ablation) | Chamber assignment · Synthetic 3 mirrors, noise 2 | candidates passing: 151,200 -> 54 | Improved |
| add Proposition 1 and 2 to chamber labeling (ablation) | Chamber assignment · Synthetic chamber labeling accuracy | labeling accuracy | Improved |
| use non-planar reference points instead of planar points (ablation) | Proposed calibration · Synthetic mirror calibration | estimation error | Improved |
| increase number of reference points (ablation) | All calibration methods · Synthetic mirror calibration | estimation error | Improved |
Closest papers by meaning
- A Linear Extrinsic Calibration of Kaleidoscopic Imaging System From Single 3D Point (CVPR 2017 · similarity 0.92)
- Neural Kaleidoscopic Space Sculpting (CVPR 2023 · similarity 0.85)
- Multicamera Calibration From Visible and Mirrored Epipoles (CVPR 2016 · similarity 0.83)
- Three-view Focal Length Recovery From Homographies (CVPR 2025 · similarity 0.80)
- Minimal Perspective Autocalibration (CVPR 2024 · similarity 0.80)
- MIRROR: Make Your Object-Level Multi-View Generation More Consistent with Training-Free Rectification (ICML 2025 · similarity 0.79)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
