AI Paper Atlas

Research map / Detection and segmentation / CNN features

Efficient Masked Autoencoders With Self-Consistency

Zhaowen Li, Yousong Zhu, Zhiyang Chen, Wei Li, Rui Zhao, Chaoyang Zhao, Ming Tang, Jinqiao Wang

TPAMI 2024 · Detection and segmentation › CNN features · approach: Convolution-transformer backbones · 10 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
sample 4 random masks per iteration instead of 1 (ablation)MAE ViT-B 200 ep · ImageNet-1k linear probingtop-1 accuracy: 58.8% -> 62.5%Improved
use parallel disjoint masks instead of pure random masks (ablation)MAE ViT-B 200 ep · ImageNet-1k linear probingtop-1 accuracy: 62.5% -> 63.4%Improved
use complementary 25%/75% masks (ablation)MAE ViT-B 200 ep · ImageNet-1k linear probingtop-1 accuracy: 58.8% -> 46.7%Hurt
replace pixel reconstruction with pure self-consistency (ablation)EMAE parallel mask · ImageNet-1k linear probingtop-1 accuracy: 63.4% -> 64.9%Improved
add pixel reconstruction to self-consistency (ablation)EMAE · ImageNet-1k linear probingtop-1 accuracy: 64.9% -> 65.0%Improved
add parallel mask strategy (ablation)MAE ViT-B 800 ep · ImageNet-1k linear probingtop-1 accuracy: 64.4% -> 68.4%Improved
add self-consistency to parallel mask (ablation)EMAE ViT-B 300 ep · ImageNet-1k linear probingtop-1 accuracy: 65.3% -> 68.4%Improved
use K=14 (13/14 mask ratio) instead of K=4 (ablation)EMAE ViT-B 800 ep · ImageNet-1k linear probingtop-1 accuracy: 70.4% -> 66.7%Hurt
use EMAE K=7 versus MAE 6/7 mask ratio (ablation)EMAE ViT-B 800 ep · ImageNet-1k linear probingtop-1 accuracy: 63.9% -> 68.1%Improved
train EMAE 1600 epochs instead of 800 (ablation)EMAE ViT-B · ImageNet-1klinear probing top-1: 70.4% -> 71.2%Improved
use EMAE instead of MAE as masked augmentor at 75% maskResNet50 · ImageNet-1ktop-1 accuracy: 75.9% -> 77.2%Improved
replace MAE (1600 ep) with EMAE (800 ep)ViT-B Mask R-CNN · COCO val2017box AP: 50.4% -> 51.4%Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy