Depth and Transient Imaging With Compressive SPAD Array Cameras

Qilin Sun, Xiong Dun, Yifan Peng, Wolfgang Heidrich

CVPR 2018 · Image generation › Image restoration · approach: Reflection removal · 23 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use DMD random patterns for compressive spatial samplingSPAD array imaging · Standard resolution chartspatial resolution: a factor of 12.5Improved
Add a diffractive microlens array to focus light onto active pixel areasSPAD sensor · SPAD sensorfill factor: 3.14% -> 52.87%Improved
Fit and deconvolve the temporal PSF before reconstructionCompressive SPAD camera · Transient imagingtemporal resolution: tens of picosecondsImproved
Subtract calibrated ambient-light and dark-count ratesCompressive SPAD reconstruction · SPAD measurementstemporal noiseImproved
Correct the spatially variant phase delay using a calibrated phase mapSPAD array depth and transient reconstruction · SPAD arrayphase accuracyImproved