AI Paper Atlas

Research map / Label-efficient and robust learning / Recognition and long-tail

Fine-Grained Change Point Detection for Topic Modeling with Pitman-Yor Process

Feifei Wang, Zimeng Zhao, Ruimin Ye, Xiaoge Gu, Xiaoling Lu

JMLR 2025 · Label-efficient and robust learning › Recognition and long-tail · approach: Multilingual language representation pretraining

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use incorrect PYP hyperparameters a=0.1, b=5 in estimation (ablation)TOPIC-PYP · Synthetic Scenario 2, true a=0.5 b=5accuracy: 0.99 -> 0.96No clear effect
use incorrect PYP hyperparameters a=0.9, b=5 in estimation (ablation)TOPIC-PYP · Synthetic Scenario 2, true a=0.5 b=5accuracy: 0.99 -> 0.98No clear effect
use incorrect PYP hyperparameter b=100 in estimation (ablation)TOPIC-PYP · Synthetic Scenario 2, true a=0.5 b=5accuracy: 0.99 -> 0.99No clear effect
unify topic modeling and change point detection (TOPIC-PYP vs two-stage methods)topic change point detection · Synthetic Scenario 1-4coherence score: 29.065 vs 3.826 (Rolling LDA), Scenario 1Improved
replace Topic-CD with TOPIC-PYPunified change point model · Synthetic Scenario 2P score: 0.318 -> 0.001Improved
replace Topic-CD with TOPIC-PYPunified change point model · Synthetic Scenario 4 (h=0)precision: 0.625 -> 0.709Improved
increase the period T (ablation)TOPIC-PYP · Synthetic, T in 10,20,30 and K in 5,10,15precision: precision decreases as T increases; recall stays above 90%Hurt
increase PYP hyperparameter a (b=5) (ablation)TOPIC-PYP · Synthetic Scenario 2precision and recall: precision and accuracy increase, recall decreasesMixed
increase PYP hyperparameter b (a=0.5) (ablation)TOPIC-PYP · Synthetic Scenario 2precision and recall: precision increases, recall decreases, accuracy nearly unchangedMixed
vary lambda, alpha and gamma (ablation)TOPIC-PYP · Synthetic Scenario 2change point detection performanceNo clear effect
use unified model instead of two-stage methodstopic change point detection · Synthetic runtimerunning timeHurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy