Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add low-high decomposition (ablation) | 3D backbone · egoPPG-DB HR (4 s) | MAE (bpm): 21.76 -> 14.80 | Improved |
| add cross-domain pretraining (ablation) | 3D backbone + low-high · egoPPG-DB HR (4 s) | MAE (bpm): 14.80 -> 12.72 | Improved |
| add cross-domain pretraining (ablation) | 3D backbone + low-high · egoPPG-DB IBI (4 s) | MAE (ms): 117.72 -> 105.91 | Improved |
| use Fourier magnitude input in pretraining (ablation) | EgoHRV · egoPPG-DB HR (4 s) | MAE (bpm): 14.87 -> 12.72 | Improved |
| add NLL objective in pretraining (ablation) | EgoHRV · egoPPG-DB HR (4 s) | MAE (bpm): 15.34 -> 12.72 | Improved |
| add NLL objective in pretraining (ablation) | EgoHRV · egoPPG-DB HR (4 s) | Pearson r: 0.08 -> 0.42 | Improved |
| use U-Net instead of 3-layer MLP encoder (ablation) | EgoHRV · egoPPG-DB HR (4 s) | MAE (bpm): 13.40 -> 12.72 | Improved |
| replace PulseFormer with EgoHRV | EgoHRV · egoPPG-DB HR (4 s) | MAE (bpm): 22.10 -> 12.72 | Improved |
| replace PulseFormer with EgoHRV | EgoHRV · egoPPG-DB SDNN | MAE (ms): 33.71 -> 10.89 | Improved |
| add HRV features instead of 60 s mean HR | TimeSformer proficiency · EgoExo4D (Ego) | top-1 accuracy (%): 44.30 -> 46.75 | Improved |
| add uncertainty log-variance to HRV features (ablation) | PhysFusion · EgoExo4D (Ego) | top-1 accuracy (%): 45.31 -> 46.75 | Improved |
| add IMU input to uncertainty head (ablation) | EgoHRV · uncertainty calibration | expected calibration error (%): 20.0 -> 9.7 | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- PhysFormer — PhysFormer: Facial Video-Based Physiological Measurement With Temporal Difference Transformer (CVPR 2022) · better on 3 of 3 shared results
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- egoEMOTION: Egocentric Vision and Physiological Signals for Emotion and Personality Recognition in Real-world Tasks (NeurIPS 2025 · similarity 0.88)
- EgoSim: An Egocentric Multi-view Simulator and Real Dataset for Body-worn Cameras during Motion and Activity (NeurIPS 2024 · similarity 0.84)
- Ego-Exo4D: Understanding Skilled Human Activity from First- and Third-Person Perspectives (CVPR 2024 · similarity 0.84)
- EEVR: A Dataset of Paired Physiological Signals and Textual Descriptions for Joint Emotion Representation Learning (NeurIPS 2024 · similarity 0.83)
- WildPPG: A Real-World PPG Dataset of Long Continuous Recordings (NeurIPS 2024 · similarity 0.83)
- EgoGen: An Egocentric Synthetic Data Generator (CVPR 2024 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.