AI Paper Atlas

Research map / 3D vision / 3D generation

PUF: Plug-and-Play Uncertainty-Aware Fusion for Online 3D Scene Graph Generation

Yi Yang, Myrna Castillo Silva, Bodo Rosenhahn, Michael Yang

ECCV 2026 · 3D vision › 3D generation · approach: Open-vocabulary 3D scene understanding · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add Dirichlet node representation with probabilistic association (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 27.9 -> 31.3Improved
add Dirichlet edge representation on top of node Dirichlet (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 31.3 -> 33.9Improved
add Dirichlet edge representation alone, without node Dirichlet (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 27.9 -> 27.9No clear effect
add relationship prior on top of node and edge Dirichlet (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 33.9 -> 46.0Improved
add Dirichlet node representation to edge plus prior (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 41.4 -> 46.0Improved
add Dirichlet node representation (ablation)PUF-Voxel · 3DSSG testrelationship recall (%): 23.7 -> 28.6Improved
add relationship prior on top of node and edge Dirichlet (ablation)PUF-Voxel · 3DSSG testrelationship recall (%): 31.3 -> 40.3Improved
add edge Dirichlet on top of node Dirichlet, no prior (ablation)PUF-Gaussian · ReplicaSSG testrelationship recall (%): 23.1 -> 25.3Improved
replace frequentist prior with probabilistic Bayesian prior (ablation)PUF-Gaussian · 3DSSG testrelationship recall (%): 43.1 -> 46.0Improved
add frequentist prior to FROSS (ablation)FROSS-Gaussian · 3DSSG testrelationship recall (%): 27.9 -> 36.7Improved
raise semantic bandwidth sigma_se from 0.3 to 0.4 (ablation)PUF-Gaussian · 3DSSG validationrelationship recall (%): 34.2 -> 29.3Hurt
lower semantic bandwidth sigma_se from 0.3 to 0.2 (ablation)PUF-Gaussian · 3DSSG validationrelationship recall (%): 34.2 -> 32.4Hurt

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy